High-performance fiber-optic hot-wire flowmeter based on surface plasmon resonance and PDMS

A novel and simple fiber-optic hot-wire flowmeter based on a polydimethylsiloxane (PDMS)-coated gold-plated multimode-no-core fiber (MNF) tip is proposed and demonstrated. The gold coating not only excites the surface plasmon resonance (SPR) effect but also absorbs the laser energy to generate heat. Additionally, the sensor probe is coated with a temperature-sensitive layer of PDMS. The flow of fluids dissipates heat, causing the PDMS to reach different thermal equilibrium temperatures corresponding to certain flow rates. The experimental results prove that the real-time response of PDMS to external microfluidics can be used to sense flow rate and temperature via monitoring the dip wavelength of SPR. The sensor achieves a maximum flow rate sensitivity of 7.27 nm/(μL/s), with a detection limit of 27.5 nL/s. The response time of the sensor to flow rate change is 1.31 s. The sensor offers high sensitivity, simple fabrication, low cost, and other advantages, thereby promoting the industrial application of all-fiber-optic flow rate sensing devices.

Authors

Institutions

Publication Details

Published
2025-05-22
DOI
https://doi.org/10.1117/12.3062870
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-performance fiber-optic hot-wire flowmeter based on surface plasmon resonance and PDMS

Shengli Pu, Weinan Liu
Advanced Fiber Optic Sensors
article

High-performance fiber-optic hot-wire flowmeter based on surface plasmon resonance and PDMS

Shengli Pu, Weinan Liu
article en

Abstract

A novel and simple fiber-optic hot-wire flowmeter based on a polydimethylsiloxane (PDMS)-coated gold-plated multimode-no-core fiber (MNF) tip is proposed and demonstrated. The gold coating not only excites the surface plasmon resonance (SPR) effect but also absorbs the laser energy to generate heat. Additionally, the sensor probe is coated with a temperature-sensitive layer of PDMS. The flow of fluids dissipates heat, causing the PDMS to reach different thermal equilibrium temperatures corresponding to certain flow rates. The experimental results prove that the real-time response of PDMS to external microfluidics can be used to sense flow rate and temperature via monitoring the dip wavelength of SPR. The sensor achieves a maximum flow rate sensitivity of 7.27 nm/(μL/s), with a detection limit of 27.5 nL/s. The response time of the sensor to flow rate change is 1.31 s. The sensor offers high sensitivity, simple fabrication, low cost, and other advantages, thereby promoting the industrial application of all-fiber-optic flow rate sensing devices.

University of Shanghai for Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 91%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-performance fiber-optic hot-wire flowmeter based on surface plasmon resonance and PDMS — Shengli Pu, Weinan Liu · (2025) | TGRS Research Map | TGRS