Hollow-core fiber Fabry-Pérot photothermal gas sensing characteristics over the temperature range of 256–354K

We study the temperature dependance of photothermal signal in a hollow-core fiber (HCF) Fabry-Perot photothermal gas sensor. The photothermal signal generally increases with decreasing temperature, due to the temperature dependent absorption and thermal properties of the gas sample in the hollow-core. The temperature variation also changes the cavity length of the Fabry-Perot, which results in pump power fluctuation in the cavity due to multi-path interference and hence the photothermal signal. This fluctuation can be reduced considerably by applying proper modulation to the pump wavelength. With an 11-cm-long HCF gas cell, we demonstrated a detection limit of ~ 6 ppb acetylene in nitrogen with a 1 s lock-in time constant. With a simple temperature compensation scheme, the photothermal signal fluctuation can be reduced from 48% to 2% over the temperature range of 256–354 K.

Authors

Institutions

Publication Details

Published
2025-05-22
DOI
https://doi.org/10.1117/12.3061611
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hollow-core fiber Fabry-Pérot photothermal gas sensing characteristics over the temperature range of 256–354K

Haihong Bao, Wei Jin, S. L. Ho, Jianhui Wu et al.
Advanced Fiber Optic Sensors
article

Hollow-core fiber Fabry-Pérot photothermal gas sensing characteristics over the temperature range of 256–354K

Haihong Bao, Wei Jin, S. L. Ho, Jianhui Wu, Pengcheng Zhao
article en

Abstract

We study the temperature dependance of photothermal signal in a hollow-core fiber (HCF) Fabry-Perot photothermal gas sensor. The photothermal signal generally increases with decreasing temperature, due to the temperature dependent absorption and thermal properties of the gas sample in the hollow-core. The temperature variation also changes the cavity length of the Fabry-Perot, which results in pump power fluctuation in the cavity due to multi-path interference and hence the photothermal signal. This fluctuation can be reduced considerably by applying proper modulation to the pump wavelength. With an 11-cm-long HCF gas cell, we demonstrated a detection limit of ~ 6 ppb acetylene in nitrogen with a 1 s lock-in time constant. With a simple temperature compensation scheme, the photothermal signal fluctuation can be reduced from 48% to 2% over the temperature range of 256–354 K.

Hong Kong Polytechnic University (HK)
Openalex Percentile: Top 91%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.