Microfluidic flowmeter using a PDMS-coated capillary

A novel flowmeter based on a whispering gallery modes (WGMs) microbottle resonator is proposed and experimentally demonstrated. WGMs are excited by a tapered fiber coupled perpendicularly to a microbottle resonator formed by polydimethylsiloxane (PDMS) deposited on the surface of the central region of a tapered silica capillary. The tapered capillary works as the microfluidic channel, allowing air to flow through the capillary with varying flow rates. A broadband light source was utilized as a heat source to heat the PDMS microbottle. The air flowing through the capillary causes a temperature decrease, leading to a refractive index (RI) decrease and a size shrinkage of the PDMS microbottle resonator. This change leads to a WGM resonance shift, the value of which can be linked to the airflow rate in the capillary. A sensitivity of 0.881 nm/sccm in the range of flow rates from 0 to 2.52 sccm has been demonstrated in our experiment. The proposed sensor can be used for low-volume flow rate measurement and offers the advantages of simplicity, high sensitivity, and miniature size.

Authors

Institutions

Publication Details

Published
2025-05-22
DOI
https://doi.org/10.1117/12.3062293
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic flowmeter using a PDMS-coated capillary

Fangfang Wei, Rayhan Habib Jibon, Anuradha Rout, Yuliya Semenova et al.
3 links
Flow Measurement and Analysis
article

Microfluidic flowmeter using a PDMS-coated capillary

Fangfang Wei, Rayhan Habib Jibon, Anuradha Rout, Yuliya Semenova, Marek Rebow, Zhe Wang, Qiang Wu, Zhuochen Wang, Anand V. R, Yiming Shen
article en

Abstract

A novel flowmeter based on a whispering gallery modes (WGMs) microbottle resonator is proposed and experimentally demonstrated. WGMs are excited by a tapered fiber coupled perpendicularly to a microbottle resonator formed by polydimethylsiloxane (PDMS) deposited on the surface of the central region of a tapered silica capillary. The tapered capillary works as the microfluidic channel, allowing air to flow through the capillary with varying flow rates. A broadband light source was utilized as a heat source to heat the PDMS microbottle. The air flowing through the capillary causes a temperature decrease, leading to a refractive index (RI) decrease and a size shrinkage of the PDMS microbottle resonator. This change leads to a WGM resonance shift, the value of which can be linked to the airflow rate in the capillary. A sensitivity of 0.881 nm/sccm in the range of flow rates from 0 to 2.52 sccm has been demonstrated in our experiment. The proposed sensor can be used for low-volume flow rate measurement and offers the advantages of simplicity, high sensitivity, and miniature size.

Northumbria University (GB), Technological University Dublin (IE)
European Commission, HORIZON EUROPE Framework Programme
Clean water and sanitation
Openalex Percentile: Top 88%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microfluidic flowmeter using a PDMS-coated capillary — Fangfang Wei, Rayhan Habib Jibon, et al. · (2025) | TGRS Research Map | TGRS