Realization of a collinear pump-probe beam configuration for a fiber-optic photothermal trace gas sensing system

We present the realization of a collinear pump-probe beam configuration for photothermal interferometry-based trace gas sensing systems using a custom-made, fiber-coupled and dichroic extrinsic Fabry-Pérot etalon. The system additionally supports the common crossed-beams, as well as an angled-beams configuration. This allows a direct comparison between the configurations and clearly demonstrates the increasing sensitivity with increasing beam overlap. For the collinear alignment, a detection limit of less than 2 ppmv (water vapor) was achieved, representing a fivefold improvement compared to the crossed-beams configuration. Additionally, a competitive normalized noise-equivalent absorption of 1.95&times;10<sup>−9</sup>cm<sup>−1</sup>W/&radic;Hz was achieved for the collinear configuration. These findings highlight the critical role of beam alignment in optimizing the performance of photothermal interferometry-based sensing systems.

Authors

Institutions

Publication Details

Published
2025-05-22
DOI
https://doi.org/10.1117/12.3062901
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Realization of a collinear pump-probe beam configuration for a fiber-optic photothermal trace gas sensing system

Manuel Tanzer, Alexander Bergmann, Benjamin Lang
Advanced Fiber Optic Sensors
article

Realization of a collinear pump-probe beam configuration for a fiber-optic photothermal trace gas sensing system

Manuel Tanzer, Alexander Bergmann, Benjamin Lang
article en

Abstract

We present the realization of a collinear pump-probe beam configuration for photothermal interferometry-based trace gas sensing systems using a custom-made, fiber-coupled and dichroic extrinsic Fabry-Pérot etalon. The system additionally supports the common crossed-beams, as well as an angled-beams configuration. This allows a direct comparison between the configurations and clearly demonstrates the increasing sensitivity with increasing beam overlap. For the collinear alignment, a detection limit of less than 2 ppmv (water vapor) was achieved, representing a fivefold improvement compared to the crossed-beams configuration. Additionally, a competitive normalized noise-equivalent absorption of 1.95&times;10<sup>−9</sup>cm<sup>−1</sup>W/&radic;Hz was achieved for the collinear configuration. These findings highlight the critical role of beam alignment in optimizing the performance of photothermal interferometry-based sensing systems.

Graz University of Technology (AT)
Affordable and clean energy
Openalex Percentile: Top 91%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.