High thermal-stability Fabry-Perot acoustic sensor with graphene diaphragm

Although graphene-based Fabry-Perot (F-P) acoustic sensor demonstrates superior performance in terms of high sensitivity and compact size, temperature fluctuation remains a challenge affecting its cavity length and sensitivity. Here, a simple and portable graphene-based F-P acoustic sensor with quartz cavity structure (QCS) is developed to achieve a significantly decreased cavity length change of 3.1 nm/°C in the tested range of 20–80 °C, 95 times smaller than a referenced acoustic sensor with ceramic cavity structure (CCS). The sensitivity variation at typical 1 kHz is reduced to 0.46 %/°C, 2.3 times smaller than the result for the latter. Moreover, the maximum voltage sensitivity at 20 °C is up to 10.65 V/Pa@17 kHz in the range of 0.1–18 kHz, which is remarkably superior to the state-of-the-art F-P acoustic sensors reported previously. The device with temperature compensation exhibits potential for applications in aerospace and emergency rescue requiring weak acoustic detection in harsh environments.

Authors

Institutions

Publication Details

Published
2025-05-22
DOI
https://doi.org/10.1117/12.3059407
Citations
1
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High thermal-stability Fabry-Perot acoustic sensor with graphene diaphragm

Zhen Wan, Cheng Li, Shuxuan Dong, Yang Liu et al.
1 citations
Advanced MEMS and NEMS Technologies
0.73
article

High thermal-stability Fabry-Perot acoustic sensor with graphene diaphragm

Zhen Wan, Cheng Li, Shuxuan Dong, Yang Liu, Shangchun Fan
article en
1 citations

Abstract

Although graphene-based Fabry-Perot (F-P) acoustic sensor demonstrates superior performance in terms of high sensitivity and compact size, temperature fluctuation remains a challenge affecting its cavity length and sensitivity. Here, a simple and portable graphene-based F-P acoustic sensor with quartz cavity structure (QCS) is developed to achieve a significantly decreased cavity length change of 3.1 nm/°C in the tested range of 20–80 °C, 95 times smaller than a referenced acoustic sensor with ceramic cavity structure (CCS). The sensitivity variation at typical 1 kHz is reduced to 0.46 %/°C, 2.3 times smaller than the result for the latter. Moreover, the maximum voltage sensitivity at 20 °C is up to 10.65 V/Pa@17 kHz in the range of 0.1–18 kHz, which is remarkably superior to the state-of-the-art F-P acoustic sensors reported previously. The device with temperature compensation exhibits potential for applications in aerospace and emergency rescue requiring weak acoustic detection in harsh environments.

Beihang University (CN)
Affordable and clean energy
Openalex Percentile: Top 28%
Advanced MEMS and NEMS Technologies
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.