Functional near-infrared spectroscopy sensor using a combined short-channel regression and frequency-division multiplexing

We designed and developed an fNIRS system that suppresses this noise by integrating a short-channel-based signal correction method and frequency division multiplexing (FDM). The results indicated that after applying short-channel regression, the effect size (Cohen’s d) increased by approximately 0.9 compared to the measurements taken before applying short-channel regression. Additionally, a significant difference in hemodynamic responses was observed between the digit span task and the control task. These findings suggest that the proposed fNIRS device is unaffected by ambient light and that short-channel regression effectively reduces noise interference. Consequently, this system can deliver accurate and stable measurements of brain activity, even in conditions where managing ambient light and surface noise is complicated.

Authors

Institutions

Publication Details

Published
2025-05-22
DOI
https://doi.org/10.1117/12.3062994
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Functional near-infrared spectroscopy sensor using a combined short-channel regression and frequency-division multiplexing

Dong‐Shin Jo, Chang‐Seok Kim, Jinho Kim, Chang Hyun Park
Analytical Chemistry and Sensors
article

Functional near-infrared spectroscopy sensor using a combined short-channel regression and frequency-division multiplexing

Dong‐Shin Jo, Chang‐Seok Kim, Jinho Kim, Chang Hyun Park
article en

Abstract

We designed and developed an fNIRS system that suppresses this noise by integrating a short-channel-based signal correction method and frequency division multiplexing (FDM). The results indicated that after applying short-channel regression, the effect size (Cohen’s d) increased by approximately 0.9 compared to the measurements taken before applying short-channel regression. Additionally, a significant difference in hemodynamic responses was observed between the digit span task and the control task. These findings suggest that the proposed fNIRS device is unaffected by ambient light and that short-channel regression effectively reduces noise interference. Consequently, this system can deliver accurate and stable measurements of brain activity, even in conditions where managing ambient light and surface noise is complicated.

Pusan National University (KR)
Openalex Percentile: Top 86%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.