Experimental Testing and Numerical Bite Simulation of Complete Acrylic Dentures in Eugnathic and Progenic Occlusal Relationships

Complete dentures are exposed to complex masticatory forces that may lead to material fatigue and eventual structural failure. Occlusal relationships, such as eugnathic and progenic, influence the distribution of these forces significantly. Understanding their biomechanical impact is essential for improving denture design and longevity. The aim of this study was to evaluate the mechanical behaviour of complete dentures under bite loads in eugnathic and progenic occlusal relationships, using both experimental testing and numerical simulations. The focus was placed on identifying the conditions that lead to initial damage and the patterns of stress distribution. The material properties of the denture base and artificial teeth were determined through experimental tensile and compressive testing on cylindrical PMMA specimens. The denture geometry was acquired via 3D tomography based on impressions of an edentulous patient. Experimental testing of the denture bite was conducted to determine the force thresholds at which the initial cracks occur. Numerical simulations were carried out using finite element analysis at bite loads of 100 N and 200 N in both occlusal types, incorporating the obtained material parameters. The experimental results showed that the first signs of denture damage occurred at 6400 N in eugnathic occlusion and 7010 N in progenic occlusion. The numerical simulations confirmed that, during occlusion, the pressure is redistributed across multiple contact points, with a broader distribution reducing the localised stress. This redistribution was more efficient in eugnathic occlusion, which reduced the risk of longitudinal cracking in acrylic teeth. In contrast, progenic occlusion showed higher susceptibility to fractures within the acrylic denture base, particularly between adjacent teeth. Both the experimental and numerical approaches demonstrated that occlusal relationships affect the mechanical resilience of complete dentures directly. The findings highlight that eugnathic occlusion offers biomechanical advantages in stress distribution, potentially reducing the risk of fracture. Incorporating occlusal analysis into denture design protocols can enhance clinical outcomes and improve prosthetic longevity.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-05-22
DOI
https://doi.org/10.3390/ma18112427
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Testing and Numerical Bite Simulation of Complete Acrylic Dentures in Eugnathic and Progenic Occlusal Relationships

Martin Pavlin, Robert Ćelić, Nenad Gubeljak, Jožef Predan
Materials
Dental Implant Techniques and Outcomes
article

Experimental Testing and Numerical Bite Simulation of Complete Acrylic Dentures in Eugnathic and Progenic Occlusal Relationships

Martin Pavlin, Robert Ćelić, Nenad Gubeljak, Jožef Predan
article en

Abstract

Complete dentures are exposed to complex masticatory forces that may lead to material fatigue and eventual structural failure. Occlusal relationships, such as eugnathic and progenic, influence the distribution of these forces significantly. Understanding their biomechanical impact is essential for improving denture design and longevity. The aim of this study was to evaluate the mechanical behaviour of complete dentures under bite loads in eugnathic and progenic occlusal relationships, using both experimental testing and numerical simulations. The focus was placed on identifying the conditions that lead to initial damage and the patterns of stress distribution. The material properties of the denture base and artificial teeth were determined through experimental tensile and compressive testing on cylindrical PMMA specimens. The denture geometry was acquired via 3D tomography based on impressions of an edentulous patient. Experimental testing of the denture bite was conducted to determine the force thresholds at which the initial cracks occur. Numerical simulations were carried out using finite element analysis at bite loads of 100 N and 200 N in both occlusal types, incorporating the obtained material parameters. The experimental results showed that the first signs of denture damage occurred at 6400 N in eugnathic occlusion and 7010 N in progenic occlusion. The numerical simulations confirmed that, during occlusion, the pressure is redistributed across multiple contact points, with a broader distribution reducing the localised stress. This redistribution was more efficient in eugnathic occlusion, which reduced the risk of longitudinal cracking in acrylic teeth. In contrast, progenic occlusion showed higher susceptibility to fractures within the acrylic denture base, particularly between adjacent teeth. Both the experimental and numerical approaches demonstrated that occlusal relationships affect the mechanical resilience of complete dentures directly. The findings highlight that eugnathic occlusion offers biomechanical advantages in stress distribution, potentially reducing the risk of fracture. Incorporating occlusal analysis into denture design protocols can enhance clinical outcomes and improve prosthetic longevity.

MaterialsVol. 18(11)
University of Zagreb (HR), University of Maribor (SI)
Openalex Percentile: Top 85%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.