Analysis of x-ray film exposure parameters using the Crookes tube for educational applications

Abstract Although the Crookes tube is widely used in academic settings to demonstrate x-ray principles, standardized experimental conditions for its application have not been established. This study aims to investigate the optimal parameters for sensitizing x-ray films using weak x-rays emitted from the Crookes tube. A Crookes tube with a Maltese cross and a high-voltage induction coil capable of applying up to 30 kV was used with small dental x-ray films. A portion of the film was shielded from x-rays using a copper foil tape. The experiments were conducted at two applied voltages (15 kV and 30 kV) and five exposure durations (2–10 s). The developed films were analysed for pixel values and contrast using ImageJ software. The results demonstrate that at an applied voltage of 15 kV with a 2 s exposure, the difference in the pixel values of the exposed and shielded areas was visually detectable. However, extending the exposure time did not significantly alter the contrast. At 30 kV, the contrast increased with longer exposure times. However, when the voltage-application time exceeded 8 s, the pixel values increased more in the shielded areas than in the exposed areas, thereby reducing the contrast increment rate. To minimize radiation exposure, the induction coil must be carefully configured. An applied voltage of 15 kV with a 2 s exposure duration effectively demonstrates x-ray presence and image formation. For quantitative contrast evaluation, effective analysis can be achieved by applying 15 kV and 30 kV for 4 s, while minimizing radiation. At 30 kV, prolonged exposure times should be avoided because of increased radiation. This experimental setup provides an effective introduction to x-ray usage for beginners. This study provides guidelines for optimizing the applied voltage and exposure time in the Crookes tube to enhance the experimental outcomes while ensuring safety.

Authors

Institutions

Publication Details

Journal
Physics Education
Published
2025-05-22
DOI
https://doi.org/10.1088/1361-6552/add782
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of x-ray film exposure parameters using the Crookes tube for educational applications

Seira Munakata, K. Ogura
Physics Education
Engineering Applied Research
article

Analysis of x-ray film exposure parameters using the Crookes tube for educational applications

Seira Munakata, K. Ogura
article en

Abstract

Abstract Although the Crookes tube is widely used in academic settings to demonstrate x-ray principles, standardized experimental conditions for its application have not been established. This study aims to investigate the optimal parameters for sensitizing x-ray films using weak x-rays emitted from the Crookes tube. A Crookes tube with a Maltese cross and a high-voltage induction coil capable of applying up to 30 kV was used with small dental x-ray films. A portion of the film was shielded from x-rays using a copper foil tape. The experiments were conducted at two applied voltages (15 kV and 30 kV) and five exposure durations (2–10 s). The developed films were analysed for pixel values and contrast using ImageJ software. The results demonstrate that at an applied voltage of 15 kV with a 2 s exposure, the difference in the pixel values of the exposed and shielded areas was visually detectable. However, extending the exposure time did not significantly alter the contrast. At 30 kV, the contrast increased with longer exposure times. However, when the voltage-application time exceeded 8 s, the pixel values increased more in the shielded areas than in the exposed areas, thereby reducing the contrast increment rate. To minimize radiation exposure, the induction coil must be carefully configured. An applied voltage of 15 kV with a 2 s exposure duration effectively demonstrates x-ray presence and image formation. For quantitative contrast evaluation, effective analysis can be achieved by applying 15 kV and 30 kV for 4 s, while minimizing radiation. At 30 kV, prolonged exposure times should be avoided because of increased radiation. This experimental setup provides an effective introduction to x-ray usage for beginners. This study provides guidelines for optimizing the applied voltage and exposure time in the Crookes tube to enhance the experimental outcomes while ensuring safety.

Physics EducationVol. 60(4)
Hokkaido University of Science (JP)
Openalex Percentile: Top 88%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.