Effect of adhesive systems on shear bond strength of metal brackets bonded to different ceramic surfaces

Abstract Objectives To evaluate the effect of adhesive systems on shear bond strength (SBS) of metal brackets bonded to different ceramic surfaces. Materials and methods This study was carried out on 120 ceramic blocks. Ceramic blocks were divided into two main groups (60 blocks of VITABLOCS Mark II in group I and 60 blocks of IPS emax CAD in group II). All ceramic blocks were embedded in acrylic blocks with their surfaces facing upward. All ceramic blocks were acid etched with 9.6% HFA followed by silane application. Each group was divided into three subgroups (20 blocks/each). Each subgroup was bonded with a different adhesive system. Subgroup I was Transbond XT, subgroup II was Blugloo, subgroup III was Assure Plus + GoTo adhesive. All ceramic blocks were light cured then stored for 24 h in distilled water before SBS test. Adhesive Remnant Index (ARI) was evaluated to determine the site of bond failure. Analysis of variance and standard Student’s t test were used to analyze the differences in SBS. The χ 2 test was used to evaluate differences in ARI scores among groups. Results Significant differences in SBS among groups were found ( P ≤ 0.05). In group I, Blugloo had the highest SBS 19.34 MPa, followed by Assure Plus 16.10 MPa while Transbond XT had the lowest SBS 12.30 MPa. In group II, Blugloo also had the highest SBS 16.83 MPa, while Transbond XT also had the lowest SBS 10.50 MPa. There were no statistically significant differences in ARI scores among the subgroups of groups I and II ( P > 0.05). Conclusions SBS of metal brackets bonded to VITABLOCS Mark II ceramics was higher than SBS of IPS emax CAD ceramics. SBS of Blugloo and Assure Plus for both VITABLOCS Mark II and for IPS emax CAD ceramics were higher than Transbond XT. SBS of metal brackets bonded to two different ceramic surfaces using three different adhesive systems were higher than the clinically accepted bond strength.

Authors

Institutions

Publication Details

Journal
Tanta Dental Journal
Published
2025-01-01
DOI
https://doi.org/10.4103/tdj.tdj_82_24
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of adhesive systems on shear bond strength of metal brackets bonded to different ceramic surfaces

shaimaa Elmarhoumy, Ghada El-Mehy, Mohamed Mostafa Mostafa Mosbah
Tanta Dental Journal
Dental materials and restorations
article

Effect of adhesive systems on shear bond strength of metal brackets bonded to different ceramic surfaces

shaimaa Elmarhoumy, Ghada El-Mehy, Mohamed Mostafa Mostafa Mosbah
article en

Abstract

Abstract Objectives To evaluate the effect of adhesive systems on shear bond strength (SBS) of metal brackets bonded to different ceramic surfaces. Materials and methods This study was carried out on 120 ceramic blocks. Ceramic blocks were divided into two main groups (60 blocks of VITABLOCS Mark II in group I and 60 blocks of IPS emax CAD in group II). All ceramic blocks were embedded in acrylic blocks with their surfaces facing upward. All ceramic blocks were acid etched with 9.6% HFA followed by silane application. Each group was divided into three subgroups (20 blocks/each). Each subgroup was bonded with a different adhesive system. Subgroup I was Transbond XT, subgroup II was Blugloo, subgroup III was Assure Plus + GoTo adhesive. All ceramic blocks were light cured then stored for 24 h in distilled water before SBS test. Adhesive Remnant Index (ARI) was evaluated to determine the site of bond failure. Analysis of variance and standard Student’s t test were used to analyze the differences in SBS. The χ 2 test was used to evaluate differences in ARI scores among groups. Results Significant differences in SBS among groups were found ( P ≤ 0.05). In group I, Blugloo had the highest SBS 19.34 MPa, followed by Assure Plus 16.10 MPa while Transbond XT had the lowest SBS 12.30 MPa. In group II, Blugloo also had the highest SBS 16.83 MPa, while Transbond XT also had the lowest SBS 10.50 MPa. There were no statistically significant differences in ARI scores among the subgroups of groups I and II ( P > 0.05). Conclusions SBS of metal brackets bonded to VITABLOCS Mark II ceramics was higher than SBS of IPS emax CAD ceramics. SBS of Blugloo and Assure Plus for both VITABLOCS Mark II and for IPS emax CAD ceramics were higher than Transbond XT. SBS of metal brackets bonded to two different ceramic surfaces using three different adhesive systems were higher than the clinically accepted bond strength.

Tanta Dental JournalVol. 22(1)
Tanta University (EG)
Openalex Percentile: Top 88%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.