Development of smart samplers and their comparison to dried serum spots for the analysis of growth hormone releasing hormone analogs using LC HRMS/MS

• Smart samplers prepared by DVS functionalization and antibody immobilization • Smart samplers and dried serum spots (DSS) applied in serum analysis by LC-HRMS/MS • GHRH analogs and doping agents sermorelin, CJC-1295 and tesamorelin determined • Smart samplers achieved higher sensitivity in detecting sermorelin • Sustainable and low-cost paper used for both smart sampler development and DSS Growth hormone-releasing hormone (GHRH) analogs, including sermorelin, CJC-1295, and tesamorelin, are prohibited in sports due to their performance-enhancing potential. Detecting these peptides remains challenging, requiring sensitive analytical techniques. This study explores the feasibility of dried serum spots (DSS) and smart samplers for detecting GHRH analogs in human serum using liquid chromatography-high-resolution tandem mass spectrometry. Smart samplers combine sampling and sample preparation in one tool; in this study smart samplers were developed using divinyl sulfone functionalized paper to immobilize antibodies for selective analyte capture. DSS and smart samplers were compared for extraction efficiency, precision, and detection capabilities. Various extraction approaches were evaluated to optimize analyte recovery followed by a blind sample study to assess detection capability at unknown concentrations. Results showed that DSS yielded higher overall signal intensities but exhibited greater variability. In contrast, smart samplers demonstrated improved reproducibility and sensitivity at lower concentrations. Smart samplers successfully identified sermorelin at 0.25 ng∙mL -1 , CJC-1295 at 4 ng∙mL -1 , and tesamorelin at 2.5 ng∙mL -1 , while DSS exhibited limitations at these concentrations. This study presents a proof-of-concept for using smart samplers and DSS in anti-doping analysis. While the results shown are promising, further optimization is needed to improve analyte recovery and sampler stability. The findings support the potential of alternative blood sampling techniques in doping control and peptide biomarker analysis.

Authors

Institutions

Publication Details

Journal
Advances in Sample Preparation
Published
2025-05-22
DOI
https://doi.org/10.1016/j.sampre.2025.100190
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of smart samplers and their comparison to dried serum spots for the analysis of growth hormone releasing hormone analogs using LC HRMS/MS

Christina Johannsen, Trine Grønhaug Halvorsen, Yvette Dehnes, Léon Reubsaet et al.
Advances in Sample Preparation
Biosensors and Analytical Detection
article

Development of smart samplers and their comparison to dried serum spots for the analysis of growth hormone releasing hormone analogs using LC HRMS/MS

Christina Johannsen, Trine Grønhaug Halvorsen, Yvette Dehnes, Léon Reubsaet, Inger Oulie, Anh Tuan Nguyen, S Shabani, Siri Dørum
article en

Abstract

• Smart samplers prepared by DVS functionalization and antibody immobilization • Smart samplers and dried serum spots (DSS) applied in serum analysis by LC-HRMS/MS • GHRH analogs and doping agents sermorelin, CJC-1295 and tesamorelin determined • Smart samplers achieved higher sensitivity in detecting sermorelin • Sustainable and low-cost paper used for both smart sampler development and DSS Growth hormone-releasing hormone (GHRH) analogs, including sermorelin, CJC-1295, and tesamorelin, are prohibited in sports due to their performance-enhancing potential. Detecting these peptides remains challenging, requiring sensitive analytical techniques. This study explores the feasibility of dried serum spots (DSS) and smart samplers for detecting GHRH analogs in human serum using liquid chromatography-high-resolution tandem mass spectrometry. Smart samplers combine sampling and sample preparation in one tool; in this study smart samplers were developed using divinyl sulfone functionalized paper to immobilize antibodies for selective analyte capture. DSS and smart samplers were compared for extraction efficiency, precision, and detection capabilities. Various extraction approaches were evaluated to optimize analyte recovery followed by a blind sample study to assess detection capability at unknown concentrations. Results showed that DSS yielded higher overall signal intensities but exhibited greater variability. In contrast, smart samplers demonstrated improved reproducibility and sensitivity at lower concentrations. Smart samplers successfully identified sermorelin at 0.25 ng∙mL -1 , CJC-1295 at 4 ng∙mL -1 , and tesamorelin at 2.5 ng∙mL -1 , while DSS exhibited limitations at these concentrations. This study presents a proof-of-concept for using smart samplers and DSS in anti-doping analysis. While the results shown are promising, further optimization is needed to improve analyte recovery and sampler stability. The findings support the potential of alternative blood sampling techniques in doping control and peptide biomarker analysis.

Advances in Sample PreparationVol. 15
Oslo University Hospital (NO), University of Oslo (NO)
Zero hunger
Openalex Percentile: Top 90%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.