Aducanumab delivery via focused ultrasound-induced transient blood–brain barrier opening in vivo

Focused ultrasound (FUS) with magnetic resonance imaging (MRI) guidance (MRgFUS) has emerged as a promising technique for enhancing drug delivery to the brain. Through the controlled oscillation of gas-encased microbubbles, FUS temporarily modulates the integrity of tight junctions, inducing localized blood-brain barrier disruption (BBBD) and allowing targeted drug passage. Aducanumab (ADU) has demonstrated efficacy in reducing amyloid pathology, yet its clinical application remains limited by the restrictive nature of the blood-brain barrier (BBB). This in vivo study aimed to evaluate the efficiency of ADU delivery facilitated by FUS-induced BBBD in the normal Institute of Cancer Research (ICR) mouse brain under two pressure conditions: 0.25 and 0.42 MPa. Following FUS sonication with MRI guidance, ADU concentrations in brain tissues and serum were measured via enzyme-linked immunosorbent assay (ELISA) at multiple time points. Histological analysis at 24 h post-FUS-BBBD was performed to assess ADU distribution, and tissue integrity was evaluated through hematoxylin and eosin (H&E) and Nissl staining to detect potential damage in the target regions. The results demonstrated that MRgFUS significantly increased ADU concentrations within the target areas without inducing substantial tissue damage. ADU delivery efficiency was directly correlated with the degree of BBBD, exhibiting a 7-fold increase at 0.25 MPa and a 60-fold increase at 0.42 MPa compared to sham controls, with distinct kinetic profiles observed for each condition. These findings highlight the potential of FUS-BBBD as a therapeutic strategy to enhance ADU delivery to the brain, reduce required infusion doses, and mitigate side effects associated with high-dose administration.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-22
DOI
https://doi.org/10.1038/s41598-025-02412-1
Citations
3
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aducanumab delivery via focused ultrasound-induced transient blood–brain barrier opening in vivo

Hyo Jin Choi, Kihyun Kwon, Mun Han, Jaeyeong Jeong et al.
3 citations
Scientific Reports
Ultrasound and Hyperthermia Applications
2.02
article

Aducanumab delivery via focused ultrasound-induced transient blood–brain barrier opening in vivo

Hyo Jin Choi, Kihyun Kwon, Mun Han, Jaeyeong Jeong, Jong‐ryul Choi, Yejin Kim, Eun‐Hee Lee, Soyeon Jeon, Woohyuk Choi
article en
3 citations

Abstract

Focused ultrasound (FUS) with magnetic resonance imaging (MRI) guidance (MRgFUS) has emerged as a promising technique for enhancing drug delivery to the brain. Through the controlled oscillation of gas-encased microbubbles, FUS temporarily modulates the integrity of tight junctions, inducing localized blood-brain barrier disruption (BBBD) and allowing targeted drug passage. Aducanumab (ADU) has demonstrated efficacy in reducing amyloid pathology, yet its clinical application remains limited by the restrictive nature of the blood-brain barrier (BBB). This in vivo study aimed to evaluate the efficiency of ADU delivery facilitated by FUS-induced BBBD in the normal Institute of Cancer Research (ICR) mouse brain under two pressure conditions: 0.25 and 0.42 MPa. Following FUS sonication with MRI guidance, ADU concentrations in brain tissues and serum were measured via enzyme-linked immunosorbent assay (ELISA) at multiple time points. Histological analysis at 24 h post-FUS-BBBD was performed to assess ADU distribution, and tissue integrity was evaluated through hematoxylin and eosin (H&E) and Nissl staining to detect potential damage in the target regions. The results demonstrated that MRgFUS significantly increased ADU concentrations within the target areas without inducing substantial tissue damage. ADU delivery efficiency was directly correlated with the degree of BBBD, exhibiting a 7-fold increase at 0.25 MPa and a 60-fold increase at 0.42 MPa compared to sham controls, with distinct kinetic profiles observed for each condition. These findings highlight the potential of FUS-BBBD as a therapeutic strategy to enhance ADU delivery to the brain, reduce required infusion doses, and mitigate side effects associated with high-dose administration.

Scientific ReportsVol. 15(1)
Baylor College of Medicine (US), Daegu-Gyeongbuk Medical Innovation Foundation (KR)
Korea Dementia Research Center, Ministry of Trade, Industry and Energy, Korea Institute for Advancement of Technology, Korea Health Industry Development Institute, INNOPOLIS Foundation, Ministry of Science and ICT, South Korea
Zero hunger
Openalex Percentile: Top 14%
Ultrasound and Hyperthermia Applications
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.