Development and Validation of a Simple UV-Vis Spectrophotometric Method for the Quantitative Determination of Amoxicillin in Pharmaceutical Dosage Forms

A simple, sensitive, and inexpensive UV/visible spectrophotometric approach was developed and validated for the quantitative measurement of amoxicillin (AMX) in pharmaceutical dosage forms. The approach demonstrated excellent linearity (r² = 0.9994) across the concentration range of 1.0-15.0 µg mL⁻¹ by measuring absorbance at 228 nm. The determined limits of detection and quantification were established at 0.56 and 1.72 µg mL-1 for AMX, respectively. Values of relative standard deviation (RSD) below 2% indicated remarkable repeatability and consistency; intra-day and inter-day studies confirmed accuracy. Recovery tests conducted at three concentration levels yielded results within the acceptable range of 94.15% to 108%, demonstrating the accuracy of the method. The validated method was successfully used to analyze various commercial amoxicillin products in tablet and capsule forms because all the tested samples met the required quality standards. These findings demonstrate that the proposed spectrophotometric method is consistent and adequate for routine quality monitoring of amoxicillin in pharmaceutical formulations.

Institutions

Publication Details

Journal
AlQalam Journal of Medical and Applied Sciences
Published
2025-05-20
DOI
https://doi.org/10.54361/ajmas.258257
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Simple UV-Vis Spectrophotometric Method for the Quantitative Determination of Amoxicillin in Pharmaceutical Dosage Forms

AlQalam Journal of Medical and Applied Sciences
Analytical Methods in Pharmaceuticals
article

Development and Validation of a Simple UV-Vis Spectrophotometric Method for the Quantitative Determination of Amoxicillin in Pharmaceutical Dosage Forms

article en

Abstract

A simple, sensitive, and inexpensive UV/visible spectrophotometric approach was developed and validated for the quantitative measurement of amoxicillin (AMX) in pharmaceutical dosage forms. The approach demonstrated excellent linearity (r² = 0.9994) across the concentration range of 1.0-15.0 µg mL⁻¹ by measuring absorbance at 228 nm. The determined limits of detection and quantification were established at 0.56 and 1.72 µg mL-1 for AMX, respectively. Values of relative standard deviation (RSD) below 2% indicated remarkable repeatability and consistency; intra-day and inter-day studies confirmed accuracy. Recovery tests conducted at three concentration levels yielded results within the acceptable range of 94.15% to 108%, demonstrating the accuracy of the method. The validated method was successfully used to analyze various commercial amoxicillin products in tablet and capsule forms because all the tested samples met the required quality standards. These findings demonstrate that the proposed spectrophotometric method is consistent and adequate for routine quality monitoring of amoxicillin in pharmaceutical formulations.

AlQalam Journal of Medical and Applied Sciences
Misurata University (LY), Sirte University (LY)
Openalex Percentile: Top 88%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.