Dosimetry Computation Based on Near-Field Measurements on a Huygens Box Surrounding the Antenna

This article presents a new technique for dosimetry assessment in realistic environments based on free-space EM-fields' measurements around the antenna thanks to a RF phasor array embedded in an EM scanner. These measured EM-fields are used in the simulation as a Huygens' box source to model the radiation from the EM-device. Note that in practice -except for the manufacturers of the EM device- the challenge is that we do not know the full details of the EM-device concretely. Such knowledge is necessary in any simulation process containing the device. The coupling of RF phasor near-field measurements with simulations (augmented measurements) are done by keeping a turned off simplified replica of the EM-device inside the Huygens' box to model the interactions between the human model and the EM-device (e.g., scattering and diffraction). Numerical simulations are done with the Finite Integration Technique (FIT) to test the accuracy and validity of the proposed approach.

Authors

Institutions

Publication Details

Published
2025-03-30
DOI
https://doi.org/10.23919/eucap63536.2025.10999870
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetry Computation Based on Near-Field Measurements on a Huygens Box Surrounding the Antenna

Marylène Cueille, Mohammad Bagheriasl, Soukaina Mifdal, Abdelrahman Ijjeh et al.
Radiation Therapy and Dosimetry
article

Dosimetry Computation Based on Near-Field Measurements on a Huygens Box Surrounding the Antenna

Marylène Cueille, Mohammad Bagheriasl, Soukaina Mifdal, Abdelrahman Ijjeh, L. Richard, Alexandre Debard, Stéphane Pannetrat, J-L. Dubard, L.B. Lopes, C. Gouriou
article en

Abstract

This article presents a new technique for dosimetry assessment in realistic environments based on free-space EM-fields' measurements around the antenna thanks to a RF phasor array embedded in an EM scanner. These measured EM-fields are used in the simulation as a Huygens' box source to model the radiation from the EM-device. Note that in practice -except for the manufacturers of the EM device- the challenge is that we do not know the full details of the EM-device concretely. Such knowledge is necessary in any simulation process containing the device. The coupling of RF phasor near-field measurements with simulations (augmented measurements) are done by keeping a turned off simplified replica of the EM-device inside the Huygens' box to model the interactions between the human model and the EM-device (e.g., scattering and diffraction). Numerical simulations are done with the Finite Integration Technique (FIT) to test the accuracy and validity of the proposed approach.

Centre National de la Recherche Scientifique (FR)
Openalex Percentile: Top 81%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.