Assessment of Extending a Two-Port Calibration to a Multi-Port Microwave Scanner

This work evaluates a sub-calibration method for a multi-port microwave imaging scanner. This decreases the complexity of a conventional full n-port calibration, albeit inserting uncertainties. The approach involves a combined 2-port full standard calibration along with a multi-port extension. It addresses systematic errors and reduces the impact of losses and phase shifts introduced by the multiplexing component of a microwave scanner, normally interfacing the 2-port transceiving stage with the multiple radiating elements. The analysis examines the calibration assumptions and validates them on a microwave scanner utilizing a 2-port vector network analyzer and a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$2\times 22$</tex> solid-state switching matrix. Repeatability and stability tests confirm the calibration's reliability, effectiveness, and permissible effect on the imaging retrieval capabilities.

Authors

Institutions

Publication Details

Published
2025-03-30
DOI
https://doi.org/10.23919/eucap63536.2025.10999292
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Extending a Two-Port Calibration to a Multi-Port Microwave Scanner

J. A. Tobón Vasquez, Lorenzo Crocco, C. Origlia, Rosa Scapaticci et al.
1 links
Microwave and Dielectric Measurement Techniques
article

Assessment of Extending a Two-Port Calibration to a Multi-Port Microwave Scanner

J. A. Tobón Vasquez, Lorenzo Crocco, C. Origlia, Rosa Scapaticci, Francesca Vipiana, D. O. Rodriguez-Duarte, M. Gugliermino
article en

Abstract

This work evaluates a sub-calibration method for a multi-port microwave imaging scanner. This decreases the complexity of a conventional full n-port calibration, albeit inserting uncertainties. The approach involves a combined 2-port full standard calibration along with a multi-port extension. It addresses systematic errors and reduces the impact of losses and phase shifts introduced by the multiplexing component of a microwave scanner, normally interfacing the 2-port transceiving stage with the multiple radiating elements. The analysis examines the calibration assumptions and validates them on a microwave scanner utilizing a 2-port vector network analyzer and a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$2\times 22$</tex> solid-state switching matrix. Repeatability and stability tests confirm the calibration's reliability, effectiveness, and permissible effect on the imaging retrieval capabilities.

Politecnico di Torino (IT), Istituto per il Rilevamento Elettromagnetico dell'Ambiente (IT), National Research Council (IT)
European Commission
Affordable and clean energy
Openalex Percentile: Top 91%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of Extending a Two-Port Calibration to a Multi-Port Microwave Scanner — J. A. Tobón Vasquez, Lorenzo Crocco, et al. · (2025) | TGRS Research Map | TGRS