Non-Invasive Skin Cancer Detection: A High-Resolution Millimeter-Wave Time Reversal Approach

This paper introduces a novel non-invasive skin cancer detection system using a high-resolution millimeter-wave time reversal imaging approach. Operating in the 2–30 GHz frequency range, the system utilizes two moving Vivaldi antennas to scan the imaging area, significantly reducing hardware complexity and cost compared to conventional systems. The system features a skin-removal technique that eliminates surface reflections, improving subsurface imaging accuracy. Through time-reversal methods, particularly the DORT algorithm, the system achieves high-resolution imaging capable of detecting both single and multiple tumors. In tests with phantoms, the system successfully identified single tumors with diameters of 5 mm and 8 mm and multiple tumors of 8 mm in close proximity. The worst-case positioning error for single tumor detection was 4 mm, and for multiple targets, 14 mm. The system also exhibited a high signal-to-clutter ratio (SCR) of up to 10.8 dB, demonstrating its effectiveness in distinguishing between benign and malignant tissues.

Authors

Institutions

Publication Details

Published
2025-03-30
DOI
https://doi.org/10.23919/eucap63536.2025.10999324
Primary Topic
Microwave Imaging and Scattering Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Invasive Skin Cancer Detection: A High-Resolution Millimeter-Wave Time Reversal Approach

Javad Ebrahimizadeh, Fatemeh Ravanbakhsh, Alireza Madannejad
1 links
Microwave Imaging and Scattering Analysis
article

Non-Invasive Skin Cancer Detection: A High-Resolution Millimeter-Wave Time Reversal Approach

Javad Ebrahimizadeh, Fatemeh Ravanbakhsh, Alireza Madannejad
article en

Abstract

This paper introduces a novel non-invasive skin cancer detection system using a high-resolution millimeter-wave time reversal imaging approach. Operating in the 2–30 GHz frequency range, the system utilizes two moving Vivaldi antennas to scan the imaging area, significantly reducing hardware complexity and cost compared to conventional systems. The system features a skin-removal technique that eliminates surface reflections, improving subsurface imaging accuracy. Through time-reversal methods, particularly the DORT algorithm, the system achieves high-resolution imaging capable of detecting both single and multiple tumors. In tests with phantoms, the system successfully identified single tumors with diameters of 5 mm and 8 mm and multiple tumors of 8 mm in close proximity. The worst-case positioning error for single tumor detection was 4 mm, and for multiple targets, 14 mm. The system also exhibited a high signal-to-clutter ratio (SCR) of up to 10.8 dB, demonstrating its effectiveness in distinguishing between benign and malignant tissues.

Islamic Azad University Medical Branch of Tehran (IR), KTH Royal Institute of Technology (SE), KU Leuven (BE)
Openalex Percentile: Top 90%
Microwave Imaging and Scattering Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Non-Invasive Skin Cancer Detection: A High-Resolution Millimeter-Wave Time Reversal Approach — Javad Ebrahimizadeh, Fatemeh Ravanbakhsh, et al. · (2025) | TGRS Research Map | TGRS