A Study on the Reduction of Frequency Points in Muscle Rupture Microwave Imaging

Injuries in the hamstring muscles are among the most common injuries in sports. We have identified a need for new low-cost diagnostic tools to facilitate accurate diagnostics for a wide range of injured athletes and the general public. Therefore we are developing a microwave-based imaging system for muscle rupture detection based on frequency domain transmission measurements. In this paper, we have investigated the effect of the number of frequencies on the image accuracy in a delay multiply and sum algorithm. The experimental results show that using about 20 frequency points in the range 0.5-2 GHz results in accurate image reconstructions. Compared to using 260 points the decrease in the relative squared error is less than 1%. This is a significant result that paves the path for the development of affordable and compact systems that can be made available widely.

Authors

Institutions

Publication Details

Published
2025-03-30
DOI
https://doi.org/10.23919/eucap63536.2025.10999374
Primary Topic
Microwave Imaging and Scattering Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study on the Reduction of Frequency Points in Muscle Rupture Microwave Imaging

Andreas Fhager, Lars E. Peterson, Laura Guerrero Orozco
3 links
Microwave Imaging and Scattering Analysis
article

A Study on the Reduction of Frequency Points in Muscle Rupture Microwave Imaging

Andreas Fhager, Lars E. Peterson, Laura Guerrero Orozco
article en

Abstract

Injuries in the hamstring muscles are among the most common injuries in sports. We have identified a need for new low-cost diagnostic tools to facilitate accurate diagnostics for a wide range of injured athletes and the general public. Therefore we are developing a microwave-based imaging system for muscle rupture detection based on frequency domain transmission measurements. In this paper, we have investigated the effect of the number of frequencies on the image accuracy in a delay multiply and sum algorithm. The experimental results show that using about 20 frequency points in the range 0.5-2 GHz results in accurate image reconstructions. Compared to using 260 points the decrease in the relative squared error is less than 1%. This is a significant result that paves the path for the development of affordable and compact systems that can be made available widely.

Chalmers University of Technology (SE), University of Gothenburg (SE)
Openalex Percentile: Top 90%
Microwave Imaging and Scattering Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.