An Advanced Generative AI-Based Anomaly Detection in IEC61850-Based Communication Messages in Smart Grids

Security incidents in digital substations can create notable difficulties for the consistent and stable functioning of power systems. To address these issues, implementing defense and mitigation strategies is essential. Identifying and detecting irregularities in information and communication technology (ICT) is vital to maintaining secure interactions between devices in digital substations. This paper proposes a task-oriented dialogue (ToD) system for anomaly detection (AD) in multicast message datasets, such as generic object-oriented substation events (GOOSE) and sampled values (SV) in digital substations using generative AI (GenAI). The proposed ToD model demonstrates significant advantages over the human-in-the-loop (HITL) approach, particularly in error rate, adaptability, and scalability. Specifically, compared to HITL, the ToD model achieves a reduction in false positives (FPs) of up to 20% and enhances the accuracy of AD by up to 17.5%, resulting in a general accuracy of 97.5%. Moreover, the system shows a substantial improvement in advanced evaluation metrics, including a Matthews Correlation Coefficient (MCC) of 0.95, highlighting its robust capability to accurately differentiate between normal and anomalous events. The ToD model adapts effectively to new attack scenarios without extensive retraining, unlike traditional machine learning (ML) models or HITL, which require frequent updates. This adaptability significantly reduces implementation time compared to HITL, as the model requires fewer manual interventions and updates. These findings are supported by a comparative analysis using standard and advanced evaluation metrics. The generation and extraction of datasets of IEC 61850 communications were performed using a hardware-in-the-loop (HIL) testbed, ensuring the robustness of the proposed approach in practical scenarios.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3571881
Citations
5
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
6.07
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Advanced Generative AI-Based Anomaly Detection in IEC61850-Based Communication Messages in Smart Grids

Aydin Zaboli, Yong‐Hwa Kim, Junho Hong
5 citations
IEEE Access
Smart Grid Security and Resilience
6.07
article

An Advanced Generative AI-Based Anomaly Detection in IEC61850-Based Communication Messages in Smart Grids

Aydin Zaboli, Yong‐Hwa Kim, Junho Hong
article en
5 citations

Abstract

Security incidents in digital substations can create notable difficulties for the consistent and stable functioning of power systems. To address these issues, implementing defense and mitigation strategies is essential. Identifying and detecting irregularities in information and communication technology (ICT) is vital to maintaining secure interactions between devices in digital substations. This paper proposes a task-oriented dialogue (ToD) system for anomaly detection (AD) in multicast message datasets, such as generic object-oriented substation events (GOOSE) and sampled values (SV) in digital substations using generative AI (GenAI). The proposed ToD model demonstrates significant advantages over the human-in-the-loop (HITL) approach, particularly in error rate, adaptability, and scalability. Specifically, compared to HITL, the ToD model achieves a reduction in false positives (FPs) of up to 20% and enhances the accuracy of AD by up to 17.5%, resulting in a general accuracy of 97.5%. Moreover, the system shows a substantial improvement in advanced evaluation metrics, including a Matthews Correlation Coefficient (MCC) of 0.95, highlighting its robust capability to accurately differentiate between normal and anomalous events. The ToD model adapts effectively to new attack scenarios without extensive retraining, unlike traditional machine learning (ML) models or HITL, which require frequent updates. This adaptability significantly reduces implementation time compared to HITL, as the model requires fewer manual interventions and updates. These findings are supported by a comparative analysis using standard and advanced evaluation metrics. The generation and extraction of datasets of IEC 61850 communications were performed using a hardware-in-the-loop (HIL) testbed, ensuring the robustness of the proposed approach in practical scenarios.

IEEE AccessVol. 13
Korea National University of Transportation (KR), University of Michigan–Dearborn (US)
Affordable and clean energy
Openalex Percentile: Top 4%
Smart Grid Security and Resilience
6.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.