Design of a Compact 868 MHz On-Body Matched Antenna for Relaying Biomedical Implants

A compact <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(40\times 40\times 0.8$</tex> mm ) 868 MHz Long Range (LoRa, 863–870 MHz) band repeater antenna is proposed for on-body relaying of biomedical implants. The antenna is designed in close proximity to a canonical three-layer tissue model and validated with simulations using three realistic human models. The antenna achieves a 12.3 % fractional bandwidth and maintains robust performance across different models with a maximum on-body gain of -8.1 dBi. Specific Absorption Rate (SAR) analysis confirms compliance with International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines, making it suitable for on-body biomedical applications.

Authors

Institutions

Publication Details

Published
2025-03-30
DOI
https://doi.org/10.23919/eucap63536.2025.10999965
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a Compact 868 MHz On-Body Matched Antenna for Relaying Biomedical Implants

Günter Vermeeren, Wout Joseph, Yizhen Yang
Wireless Body Area Networks
article

Design of a Compact 868 MHz On-Body Matched Antenna for Relaying Biomedical Implants

Günter Vermeeren, Wout Joseph, Yizhen Yang
article en

Abstract

A compact <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(40\times 40\times 0.8$</tex> mm ) 868 MHz Long Range (LoRa, 863–870 MHz) band repeater antenna is proposed for on-body relaying of biomedical implants. The antenna is designed in close proximity to a canonical three-layer tissue model and validated with simulations using three realistic human models. The antenna achieves a 12.3 % fractional bandwidth and maintains robust performance across different models with a maximum on-body gain of -8.1 dBi. Specific Absorption Rate (SAR) analysis confirms compliance with International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines, making it suitable for on-body biomedical applications.

Ghent University (BE)
Openalex Percentile: Top 90%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.