Multi‐Shot Diffusion Imaging Using Motion Compensation Diffusion Encoding Waveforms and EPI With Keyhole

Motion-induced shot-to-shot phase variation and strong image aliasing artifacts are common in diffusion weighted imaging (DWI) multi-shot EPI (MS-EPI). Herein, motion-compensated diffusion encoding waveforms were used to minimize shot-to-shot phase variation, and an MS-EPI with Keyhole (MS-EPIK) trajectory was evaluated to mitigate image aliasing. MS-EPI and MS-EPIK with non-motion compensated (M<sub>0</sub>), first order (M<sub>0</sub>M<sub>1</sub>), and first & second order (M<sub>0</sub>M<sub>1</sub>M<sub>2</sub>) motion-compensated diffusion encoding waveforms and a reference single-shot (SS-EPI) acquisition with M<sub>0</sub> diffusion encoding were acquired in vivo at 3T in five volunteers in the brain, liver, and heart. Mean diffusivity (MD) and fraction of anisotropy (FA) were reported in the brain and heart, and the apparent diffusion coefficient (ADC) in the liver. No statistical differences in MD and FA between the SS-EPI, MS-EPIK, and MS-EPI when using the M0M1M2 waveform were found in white and gray matter. In the right liver lobe, statistical differences were found between the ADC of the SS-EPI and MS-EPIK using the M<sub>0</sub>, M<sub>0</sub>M<sub>1</sub>, and M<sub>0</sub>M<sub>1</sub>M<sub>2</sub> waveforms (p < 0.001) and with MS-EPI using M<sub>0</sub>M<sub>1</sub>M<sub>2</sub> (p < 0.001). No differences were observed in MD and FA in the heart between SS-EPI, MS-EPI, and MS-EPIK in the heart. MS-EPIK is less sensitive to image aliasing than MS-EPI approach but remains susceptible to image distortion. Overall, M<sub>0</sub>M<sub>1</sub>M<sub>2</sub> waveforms were found to be the best approach to mitigate shot-to-shot phase variation for MS-EPI in the brain, liver, and heart.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-05-20
DOI
https://doi.org/10.1002/nbm.70022
Citations
1
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi‐Shot Diffusion Imaging Using Motion Compensation Diffusion Encoding Waveforms and EPI With Keyhole

Magalie Viallon, Kévin Moulin, Kelvin Chow, Thomas Troalen et al.
1 citations
NMR in Biomedicine
Advanced Neuroimaging Techniques and Applications
1.36
article

Multi‐Shot Diffusion Imaging Using Motion Compensation Diffusion Encoding Waveforms and EPI With Keyhole

Magalie Viallon, Kévin Moulin, Kelvin Chow, Thomas Troalen, Pierre Croisille, Daniel B. Ennis, Tyler E. Cork
article en
1 citations

Abstract

Motion-induced shot-to-shot phase variation and strong image aliasing artifacts are common in diffusion weighted imaging (DWI) multi-shot EPI (MS-EPI). Herein, motion-compensated diffusion encoding waveforms were used to minimize shot-to-shot phase variation, and an MS-EPI with Keyhole (MS-EPIK) trajectory was evaluated to mitigate image aliasing. MS-EPI and MS-EPIK with non-motion compensated (M<sub>0</sub>), first order (M<sub>0</sub>M<sub>1</sub>), and first & second order (M<sub>0</sub>M<sub>1</sub>M<sub>2</sub>) motion-compensated diffusion encoding waveforms and a reference single-shot (SS-EPI) acquisition with M<sub>0</sub> diffusion encoding were acquired in vivo at 3T in five volunteers in the brain, liver, and heart. Mean diffusivity (MD) and fraction of anisotropy (FA) were reported in the brain and heart, and the apparent diffusion coefficient (ADC) in the liver. No statistical differences in MD and FA between the SS-EPI, MS-EPIK, and MS-EPI when using the M0M1M2 waveform were found in white and gray matter. In the right liver lobe, statistical differences were found between the ADC of the SS-EPI and MS-EPIK using the M<sub>0</sub>, M<sub>0</sub>M<sub>1</sub>, and M<sub>0</sub>M<sub>1</sub>M<sub>2</sub> waveforms (p < 0.001) and with MS-EPI using M<sub>0</sub>M<sub>1</sub>M<sub>2</sub> (p < 0.001). No differences were observed in MD and FA in the heart between SS-EPI, MS-EPI, and MS-EPIK in the heart. MS-EPIK is less sensitive to image aliasing than MS-EPI approach but remains susceptible to image distortion. Overall, M<sub>0</sub>M<sub>1</sub>M<sub>2</sub> waveforms were found to be the best approach to mitigate shot-to-shot phase variation for MS-EPI in the brain, liver, and heart.

NMR in BiomedicineVol. 38(7)
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Inserm (FR), VA Palo Alto Health Care System (US), Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé (FR), Siemens (France) (FR), Siemens Healthcare (United States) (US), Centre Hospitalier Universitaire de Saint-Étienne (FR), Stanford University (US)
National Science Foundation, Agence Nationale de la Recherche, Université Claude Bernard Lyon 1, Siemens Healthineers, National Institutes of Health, National Heart, Lung, and Blood Institute
Openalex Percentile: Top 20%
Advanced Neuroimaging Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.