Shear strength evaluation of headed stud connectors in steel-concrete composite structures with hollow core slabs

Abstract This paper investigates the shear strength of connectors in steel-concrete composite structures, with a specific focus on precast hollow core slabs. Push-out tests were conducted to assess the load-bearing capacity of headed shear studs, welded to the steel profile and embedded in cast-in-place concrete. The experimental analysis was complemented by a numerical study using the finite element method (FEM), allowing for a detailed evaluation of the behavior of the connectors under shear forces. A parametric study was performed to examine the effects of concrete compressive strength and stud yield strength on the shear resistance of the connection. The results demonstrated a good correlation between experimental tests and numerical predictions, though theoretical formulas based on standards tended to overestimate the connector capacity. This research emphasizes the importance of accurately characterizing shear connectors to ensure the proper performance of composite structures, particularly in applications involving hollow core slabs.

Authors

Institutions

Publication Details

Journal
Ambiente Construído
Published
2025-01-01
DOI
https://doi.org/10.1590/s1678-86212025000100880
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shear strength evaluation of headed stud connectors in steel-concrete composite structures with hollow core slabs

Marcela Novischi Kataoka
Ambiente Construído
Structural Load-Bearing Analysis
article

Shear strength evaluation of headed stud connectors in steel-concrete composite structures with hollow core slabs

Marcela Novischi Kataoka
article en

Abstract

Abstract This paper investigates the shear strength of connectors in steel-concrete composite structures, with a specific focus on precast hollow core slabs. Push-out tests were conducted to assess the load-bearing capacity of headed shear studs, welded to the steel profile and embedded in cast-in-place concrete. The experimental analysis was complemented by a numerical study using the finite element method (FEM), allowing for a detailed evaluation of the behavior of the connectors under shear forces. A parametric study was performed to examine the effects of concrete compressive strength and stud yield strength on the shear resistance of the connection. The results demonstrated a good correlation between experimental tests and numerical predictions, though theoretical formulas based on standards tended to overestimate the connector capacity. This research emphasizes the importance of accurately characterizing shear connectors to ensure the proper performance of composite structures, particularly in applications involving hollow core slabs.

Ambiente ConstruídoVol. 25
Universidade de São Paulo (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Openalex Percentile: Top 89%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Shear strength evaluation of headed stud connectors in steel-concrete composite structures with hollow core slabs — Marcela Novischi Kataoka · Ambiente Construído (2025) | TGRS Research Map | TGRS