PCCNN: A CNN classification model integrating EEG time-frequency features for stroke classification

Stroke classification is crucial for timely diagnosis and treatment, as it helps differentiate between hemorrhagic and ischemic strokes, which require distinct clinical interventions. This paper proposes a stroke classification method using multi-channel electroencephalography (EEG) data. Unlike single-channel data or simple multi-channel concatenation, our method processes EEG data as a channel matrix, significantly improving classification performance. We employ two complementary feature extraction techniques: discrete wavelet transform (DWT) and empirical mode decomposition (EMD). DWT extracts multi-scale wavelet coefficients from stroke-related frequency bands, while EMD decomposes EEG signals into intrinsic mode functions (IMFs), representing narrowband oscillation components. To enhance feature quality, we propose a hybrid selection method that integrates four metrics—information entropy, power spectral density (PSD) distance, statistical significance, and maximum information coefficient (MIC)—to comprehensively evaluate IMFs. This method accounts for both the intrinsic information content of EEG signals and the inter-class differences between hemorrhagic and ischemic stroke subjects. Furthermore, this paper designs a pyramid cascade convolutional neural network (PCCNN) model with multi-branch independent learning and hierarchical fusion. Each DWT and EMD feature is processed by an independent one-dimensional convolutional neural networks (1D-CNN) branch for targeted extraction. A pyramid fusion mechanism integrates branch outputs into a fused feature vector, enabling the feature interaction through a top-level fusion CNN. Experimental results demonstrate that the proposed method, which integrates channel matrix processing, high-quality DWT and EMD feature selection, and multi-branch feature fusion, significantly outperforms single-feature methods. The fusion feature achieves a classification accuracy of 99.48%, effectively distinguishing EEG data of hemorrhagic and ischemic stroke.

Authors

Institutions

Publication Details

Journal
Cognitive Robotics
Published
2025-01-01
DOI
https://doi.org/10.1016/j.cogr.2025.05.002
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PCCNN: A CNN classification model integrating EEG time-frequency features for stroke classification

Fengyun Hu, Teng Wang, Fenglian Li, Wenhui Jia et al.
Cognitive Robotics
EEG and Brain-Computer Interfaces
article

PCCNN: A CNN classification model integrating EEG time-frequency features for stroke classification

Fengyun Hu, Teng Wang, Fenglian Li, Wenhui Jia, Jia Yang
article en

Abstract

Stroke classification is crucial for timely diagnosis and treatment, as it helps differentiate between hemorrhagic and ischemic strokes, which require distinct clinical interventions. This paper proposes a stroke classification method using multi-channel electroencephalography (EEG) data. Unlike single-channel data or simple multi-channel concatenation, our method processes EEG data as a channel matrix, significantly improving classification performance. We employ two complementary feature extraction techniques: discrete wavelet transform (DWT) and empirical mode decomposition (EMD). DWT extracts multi-scale wavelet coefficients from stroke-related frequency bands, while EMD decomposes EEG signals into intrinsic mode functions (IMFs), representing narrowband oscillation components. To enhance feature quality, we propose a hybrid selection method that integrates four metrics—information entropy, power spectral density (PSD) distance, statistical significance, and maximum information coefficient (MIC)—to comprehensively evaluate IMFs. This method accounts for both the intrinsic information content of EEG signals and the inter-class differences between hemorrhagic and ischemic stroke subjects. Furthermore, this paper designs a pyramid cascade convolutional neural network (PCCNN) model with multi-branch independent learning and hierarchical fusion. Each DWT and EMD feature is processed by an independent one-dimensional convolutional neural networks (1D-CNN) branch for targeted extraction. A pyramid fusion mechanism integrates branch outputs into a fused feature vector, enabling the feature interaction through a top-level fusion CNN. Experimental results demonstrate that the proposed method, which integrates channel matrix processing, high-quality DWT and EMD feature selection, and multi-branch feature fusion, significantly outperforms single-feature methods. The fusion feature achieves a classification accuracy of 99.48%, effectively distinguishing EEG data of hemorrhagic and ischemic stroke.

Cognitive RoboticsVol. 5
Shanxi Province Hospital of Traditional Chinese Medicine (CN), Shanxi Cardiovascular Hospital (CN), Taiyuan University of Science and Technology (CN), China Academy of Launch Vehicle Technology (CN), Taiyuan University of Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 89%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.