Exploring the degradation mechanism of bisphenol-A with low Fe2+&H2O2 content and the toxicity evolution of oxidation intermediates

Efficient and cost-effective removal of emerging contaminants from water bodies has become a global priority. This study assessed the degradation efficiency of bisphenol-A (BPA) at varying Fe 2+ &H 2 O 2 (molar ratio 1:1) concentrations. In addition, the degradation mechanism of BPA by Fe 2+ &H 2 O 2 and the evolution of toxicity in intermediates were examined. The results indicated that, no additional acid is needed, with a Fe 2+ &H 2 O 2 concentration at 0.15 mM and a reaction time of 20 min, and the degradation efficiency of BPA exceeded 90%; this is primarily because the oxidation still occurred when Fe 2+ &H 2 O 2 was added to neutral BPA solutions, possibly leading to the conversion of the active functional groups of BPA into carboxyl groups. The deprotonation of these carboxyl groups provided the acidic conditions necessary for Fenton oxidation, thereby possibly facilitating further degradation of BPA and the formation of more carboxyl-rich intermediates, replenishing acidity for Fenton reactions and promoting continuous oxidation. Moreover, highly toxic intermediates are likely to form during the degradation of BPA at a 0.05-0.1 mM Fe 2+ &H 2 O 2 concentrations, but this tendency decreases substantially with increasing Fe 2+ &H 2 O 2 concentrations. At a Fe 2+ &H 2 O 2 concentration of 0.2 mM, the intermediates were predominantly low-toxicity or even nontoxic. These findings highlight the importance of monitoring toxicity evolution and the conditions favorable for the formation of low-toxic or nontoxic intermediates in the removal of emerging contaminants. To further validate the applicability of this method, p-chloroxylenol (PCMX) and paracetamol (PAM) were also tested under identical conditions, and both showed high degradation efficiencies under neutral pH. • BPA could be effectively degraded by low amount of Fe 2+ &H 2 O 2 without added acidity • The oxidation still occurred when Fe 2+ &H 2 O 2 was added to neutral BPA solutions • Continuous oxidation of Fe 2+ &H 2 O 2 due to the formation of carboxyl-rich intermediates • Controlling the dosage of Fe 2+ &H 2 O 2 can convert BPA into low- or non-toxic compounds.

Authors

Institutions

Publication Details

Journal
Water Cycle
Published
2025-01-01
DOI
https://doi.org/10.1016/j.watcyc.2025.05.005
Citations
2
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring the degradation mechanism of bisphenol-A with low Fe2+&H2O2 content and the toxicity evolution of oxidation intermediates

Danxi Huang, Jinwen Wang, Rui Miao, Haoxue Ran et al.
2 citations
Water Cycle
Advanced oxidation water treatment
1.63
article

Exploring the degradation mechanism of bisphenol-A with low Fe2+&H2O2 content and the toxicity evolution of oxidation intermediates

Danxi Huang, Jinwen Wang, Rui Miao, Haoxue Ran, Xin Zhang, Yanfei Li, Yifan Yang, Xiaorong Meng, Lei Wang
article en
2 citations

Abstract

Efficient and cost-effective removal of emerging contaminants from water bodies has become a global priority. This study assessed the degradation efficiency of bisphenol-A (BPA) at varying Fe 2+ &H 2 O 2 (molar ratio 1:1) concentrations. In addition, the degradation mechanism of BPA by Fe 2+ &H 2 O 2 and the evolution of toxicity in intermediates were examined. The results indicated that, no additional acid is needed, with a Fe 2+ &H 2 O 2 concentration at 0.15 mM and a reaction time of 20 min, and the degradation efficiency of BPA exceeded 90%; this is primarily because the oxidation still occurred when Fe 2+ &H 2 O 2 was added to neutral BPA solutions, possibly leading to the conversion of the active functional groups of BPA into carboxyl groups. The deprotonation of these carboxyl groups provided the acidic conditions necessary for Fenton oxidation, thereby possibly facilitating further degradation of BPA and the formation of more carboxyl-rich intermediates, replenishing acidity for Fenton reactions and promoting continuous oxidation. Moreover, highly toxic intermediates are likely to form during the degradation of BPA at a 0.05-0.1 mM Fe 2+ &H 2 O 2 concentrations, but this tendency decreases substantially with increasing Fe 2+ &H 2 O 2 concentrations. At a Fe 2+ &H 2 O 2 concentration of 0.2 mM, the intermediates were predominantly low-toxicity or even nontoxic. These findings highlight the importance of monitoring toxicity evolution and the conditions favorable for the formation of low-toxic or nontoxic intermediates in the removal of emerging contaminants. To further validate the applicability of this method, p-chloroxylenol (PCMX) and paracetamol (PAM) were also tested under identical conditions, and both showed high degradation efficiencies under neutral pH. • BPA could be effectively degraded by low amount of Fe 2+ &H 2 O 2 without added acidity • The oxidation still occurred when Fe 2+ &H 2 O 2 was added to neutral BPA solutions • Continuous oxidation of Fe 2+ &H 2 O 2 due to the formation of carboxyl-rich intermediates • Controlling the dosage of Fe 2+ &H 2 O 2 can convert BPA into low- or non-toxic compounds.

Water CycleVol. 6
Xi'an University of Architecture and Technology (CN), Northwest University (CN), Xi'an University of Technology (CN)
Openalex Percentile: Top 17%
Advanced oxidation water treatment
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.