Implementation of Double-Side Calibration and Measurement for Q-Band 50GHz Application

The double-side calibration and measurement on probing system for single-end and differential signals are presented in this paper. The common calibration kit in the market is including below patterns: Open, Short, Load, and Thru for SOLT/SOLR standard calibration method, but there is still no standard thru/reciprocal pattern for double-side measurement system now, therefore we design a reciprocal kit which is applicable for GSG-150um and GSGSG-150um RF probe and the frequency is up to 60GHz. The reciprocal kit is designed in the 4-layer stack up and simulated in ANSYS HFSS software, the return loss is under -10dB from DC to 60GHz frequency range, and the insertion loss is -0.6dB at 60GHz. The actual measurement results after calibration with SOLR showed -10dB of the return loss under 60GHz, and -1dB of insertion loss at 60GHz. Finally, we successfully calibrated the double-side differential system by the reciprocal kit in Q-band 50GHz and measured the two transmission lines with total 36mm length. First transmission line is all built in one layer, and the second one is divided in two layers. The measurement results showed the trace in one layer is better about 0.56dB at 30GHz.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.23919/icep-iaac64884.2025.11002939
Primary Topic
Radio Frequency Integrated Circuit Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of Double-Side Calibration and Measurement for Q-Band 50GHz Application

Vito Lin, Chia-Chu Lai, Sam Lin, Yu-Po Wang et al.
Radio Frequency Integrated Circuit Design
article

Implementation of Double-Side Calibration and Measurement for Q-Band 50GHz Application

Vito Lin, Chia-Chu Lai, Sam Lin, Yu-Po Wang, Andrew H. Kang
article en

Abstract

The double-side calibration and measurement on probing system for single-end and differential signals are presented in this paper. The common calibration kit in the market is including below patterns: Open, Short, Load, and Thru for SOLT/SOLR standard calibration method, but there is still no standard thru/reciprocal pattern for double-side measurement system now, therefore we design a reciprocal kit which is applicable for GSG-150um and GSGSG-150um RF probe and the frequency is up to 60GHz. The reciprocal kit is designed in the 4-layer stack up and simulated in ANSYS HFSS software, the return loss is under -10dB from DC to 60GHz frequency range, and the insertion loss is -0.6dB at 60GHz. The actual measurement results after calibration with SOLR showed -10dB of the return loss under 60GHz, and -1dB of insertion loss at 60GHz. Finally, we successfully calibrated the double-side differential system by the reciprocal kit in Q-band 50GHz and measured the two transmission lines with total 36mm length. First transmission line is all built in one layer, and the second one is divided in two layers. The measurement results showed the trace in one layer is better about 0.56dB at 30GHz.

Siliconware Precision Industries (Taiwan) (TW)
Affordable and clean energy
Openalex Percentile: Top 91%
Radio Frequency Integrated Circuit Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.