Effect of emergence profile and space gap size on excess cement in cement-retained implant reconstructions
The results emphasized that a straight profile with a smaller gap size should be considered to reduce the excess cement. However, due to the small sample size of the study, further analyses with different types of materials, angles of deformation, and gap sizes are required to reveal the exact relationship between excess cement and the design specifications.
Authors
- Sajjad Farashi (ORCID: https://orcid.org/0000-0002-5082-6391)
- Asgar Farahnaki
- Sara Khazaei (ORCID: https://orcid.org/0000-0001-8589-8611)
- Meysam Mahabadi
- Saeed Nikanjam (ORCID: https://orcid.org/0000-0002-5353-583X)
- Shiva Shahabi (ORCID: https://orcid.org/0000-0001-7458-9629)
- Fariborz Vafaee (ORCID: https://orcid.org/0000-0001-5988-2819)
Institutions
- Hamedan University of Medical Sciences (IR)
- Islamic Azad University, Isfahan (IR)
Publication Details
- Journal
- Journal of Advanced Periodontology & Implant Dentistry
- Published
- 2025-04-21
- DOI
- https://doi.org/10.34172/japid.025.2292
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Hamadan University of Medical Sciences