The Role of PV-Integrated Double-Skin Facades in Achieving Net-Zero Carbon Emissions in Commercial Buildings in Morocco

The construction and operation of commercial buildings significantly contribute to global greenhouse gas emissions. This study investigates the effectiveness of photovoltaic (PV)-integrated double-skin facades (DSFs) in reducing operational energy use and carbon emissions in Moroccan commercial buildings. Using dynamic energy simulations, various DSF glazing configurations were analyzed for their impact on heating and cooling energy demand, electricity consumption, and CO 2 emissions. The results reveal that PV-integrated triple glazing reduces cooling energy demand by nearly 10% and decreases total electricity consumption by about 5% annually. Compared to single glazing, this configuration achieves an additional 2.85% reduction in CO₂ emissions. Despite minor differences in solar energy conversion efficiency, the system maintains high levels of on-site renewable energy generation. These findings highlight the potential of PV-DSF systems to support Morocco’s net-zero carbon goals by enhancing building energy performance. However, seasonal variations in performance suggest the need for energy storage integration to achieve year-round carbon neutrality. The study recommends further research focusing on experimental validation and the large-scale implementation potential of PV-DSF solutions in the commercial building sector.

Authors

Institutions

Publication Details

Journal
EPJ Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/epjconf/202532602003
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Role of PV-Integrated Double-Skin Facades in Achieving Net-Zero Carbon Emissions in Commercial Buildings in Morocco

Omar Ansari, Abdellah Bah, Mustapha Malha, Abdessamad Idouanaou
1 citations
EPJ Web of Conferences
Building Energy and Comfort Optimization
1.01
article

The Role of PV-Integrated Double-Skin Facades in Achieving Net-Zero Carbon Emissions in Commercial Buildings in Morocco

Omar Ansari, Abdellah Bah, Mustapha Malha, Abdessamad Idouanaou
article en
1 citations

Abstract

The construction and operation of commercial buildings significantly contribute to global greenhouse gas emissions. This study investigates the effectiveness of photovoltaic (PV)-integrated double-skin facades (DSFs) in reducing operational energy use and carbon emissions in Moroccan commercial buildings. Using dynamic energy simulations, various DSF glazing configurations were analyzed for their impact on heating and cooling energy demand, electricity consumption, and CO 2 emissions. The results reveal that PV-integrated triple glazing reduces cooling energy demand by nearly 10% and decreases total electricity consumption by about 5% annually. Compared to single glazing, this configuration achieves an additional 2.85% reduction in CO₂ emissions. Despite minor differences in solar energy conversion efficiency, the system maintains high levels of on-site renewable energy generation. These findings highlight the potential of PV-DSF systems to support Morocco’s net-zero carbon goals by enhancing building energy performance. However, seasonal variations in performance suggest the need for energy storage integration to achieve year-round carbon neutrality. The study recommends further research focusing on experimental validation and the large-scale implementation potential of PV-DSF solutions in the commercial building sector.

EPJ Web of ConferencesVol. 326
Mohammed V University (MA)
Openalex Percentile: Top 25%
Building Energy and Comfort Optimization
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Role of PV-Integrated Double-Skin Facades in Achieving Net-Zero Carbon Emissions in Commercial Buildings in Morocco — Omar Ansari, Abdellah Bah, et al. · EPJ Web of Conferences (2025) | TGRS Research Map | TGRS