Oxidation of a ZrN knee implant coating under in-vitro wear simulation

Before knee implants are used in clinical applications, in-vitro wear simulation is essential for predicting their reliability and longevity. This study investigated the representativeness of in-vitro wear simulation concerning oxide formation on a ZrN multilayer-coated knee implant. Four different locations on one in-vitro tested sample were analyzed using scanning (transmission) electron microscopy (SEM/TEM). The sample was subjected to 5 million gait cycles according to ISO 14242-1:2002 in newborn calf serum at body temperature, equivalent to ∼ 3-5 years in-vivo. The formed surface oxides were compared with a previously investigated as-fabricated femoral component and an 'in-vivo' implant explanted after approximately two years due to early aseptic loosening. The results showed the presence of an oxide on all investigated surfaces with varying thicknesses (15-280 nm). Hence, all oxides were thicker than what would be expected from native oxidation of ZrN. Oxide composition, thickness and microstructure were comparable between in-vitro and in-vivo samples, except one outlier on the in-vitro sample (280 nm thick oxide). However, the distribution of the colored areas was not comparable: the in-vivo sample exhibited a non-articulating area completely purplish colored (art. area golden), whereas colored areas on the in-vitro sample were distributed inhomogenously. Differences in loading conditions, presence of embedded particles, exposure duration and fluids could explain these variations.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2025-05-20
DOI
https://doi.org/10.1016/j.jmbbm.2025.107069
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Oxidation of a ZrN knee implant coating under in-vitro wear simulation

Mattias Thuvander, Gustav Eriksson, Jens Schwiesau, Ana Laura Puente Reyna et al.
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Metal and Thin Film Mechanics
article

Oxidation of a ZrN knee implant coating under in-vitro wear simulation

Mattias Thuvander, Gustav Eriksson, Jens Schwiesau, Ana Laura Puente Reyna, Martin Andersson, Julia Rau
article en

Abstract

Before knee implants are used in clinical applications, in-vitro wear simulation is essential for predicting their reliability and longevity. This study investigated the representativeness of in-vitro wear simulation concerning oxide formation on a ZrN multilayer-coated knee implant. Four different locations on one in-vitro tested sample were analyzed using scanning (transmission) electron microscopy (SEM/TEM). The sample was subjected to 5 million gait cycles according to ISO 14242-1:2002 in newborn calf serum at body temperature, equivalent to ∼ 3-5 years in-vivo. The formed surface oxides were compared with a previously investigated as-fabricated femoral component and an 'in-vivo' implant explanted after approximately two years due to early aseptic loosening. The results showed the presence of an oxide on all investigated surfaces with varying thicknesses (15-280 nm). Hence, all oxides were thicker than what would be expected from native oxidation of ZrN. Oxide composition, thickness and microstructure were comparable between in-vitro and in-vivo samples, except one outlier on the in-vitro sample (280 nm thick oxide). However, the distribution of the colored areas was not comparable: the in-vivo sample exhibited a non-articulating area completely purplish colored (art. area golden), whereas colored areas on the in-vitro sample were distributed inhomogenously. Differences in loading conditions, presence of embedded particles, exposure duration and fluids could explain these variations.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 169
Aesculap (United States) (US), Chalmers University of Technology (SE), Ludwig-Maximilians-Universität München (DE)
Deutsche Forschungsgemeinschaft, Knut och Alice Wallenbergs Stiftelse, Vetenskapsrådet, Marcus och Amalia Wallenbergs minnesfond
Openalex Percentile: Top 88%
Metal and Thin Film Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.