Task specific assessment of particle exposure and low-cost sensor performance in indoor construction environments
In this study, a workplace measurement campaign was conducted during indoor renovation of two apartments following panel removal, wallpaper removal (dry/wet), sweeping (dry/wet), and floor removal (including insulation) tasks. Measurements with a low-cost sensor (LCS; OPC-N3; Alphasense) was compared to a benchmark optical particle sizer (OPS, TSI Model 3330) to assess the applicability of this LCS in a construction worker environment. Additionally, ultrafine particle concentrations (<0.1 μm) were measured using a mobility particle sizer (NanoScan, TSI Model 3091) and a diffusion size classifier (DiSCmini). The highest particle number concentrations (PNC) were found during floor removal, dry sweeping, and wallpaper removal, where 63% of particles were ultrafine (<0.1 μm) and 96% were smaller than 2.5 μm (PM 2.5 ). The PM 10 (particulate matter with a diameter < 10 μm) concentrations measured during some tasks exceeded the occupational exposure limit of 10 mg m -3 for total dust with values from 0.3 to 11 mg m -3 . Analytical electron microscopy analysis revealed exposure to compounds such as talc, titania, quartz, and potential asbestos. Water-based dust control methods reduced PNC by at least 84%, highlighting their effectiveness in mitigating exposure. LCS generally underestimated particle concentrations, particularly for PM 1 , which was underestimated ranging from 31% to 92%. The largest discrepancies occurred during high concentrations in the presence of ultrafine particles, such as floor removal and dry wallpaper removal. This study also emphasizes the importance of multi-metric measurements and breathing zone assessments to accurately evaluate worker exposure and improve occupational safety. • Floor removal, dry sweeping, and wallpaper removal generate high particle exposure, exceeding PM 10 limits. • Low-cost sensors underestimate PM 1 concentrations, especially in high dust environments. • Water-based dust suppression reduces particle number concentrations by at least 84%. • Talc, titanium dioxide, quartz, and potential asbestos detected in indoor construction dust. • Personal dust exposure measurements are more accurate than stationary monitoring.
Authors
- Ana Sofia Fonseca (ORCID: https://orcid.org/0000-0002-1424-6365)
- J. Rasmussen (ORCID: https://orcid.org/0000-0002-3947-1518)
- Keld Alstrup Jensen (ORCID: https://orcid.org/0000-0002-2764-3634)
- Anders Brostrøm (ORCID: https://orcid.org/0000-0002-0128-1508)
- Thomas N. Jensen (ORCID: https://orcid.org/0000-0003-2612-3693)
- Jesper Baldtzer Liisberg (ORCID: https://orcid.org/0000-0001-6620-5111)
- Tom Cole‐Hunter (ORCID: https://orcid.org/0000-0002-6827-6084)
- Søren Møller (ORCID: https://orcid.org/0000-0003-3213-6423)
- Josephine Thalmann
- Frederika Husovská
Institutions
- University of Copenhagen (DK)
- Danish Technological Institute (DK)
- National Research Centre for the Working Environment (DK)
Publication Details
- Journal
- Atmospheric Environment X
- Published
- 2025-04-01
- DOI
- https://doi.org/10.1016/j.aeaoa.2025.100336
- Citations
- 1
- Primary Topic
- Air Quality Monitoring and Forecasting
- Type
- article
- Field-Weighted Citation Impact
- 0.80