Integration of AC bias-stabilized SiNRFETs with microscale Ag/AgCl pseudo-reference electrodes for lab-on-chip biosensing application

Ion-sensitive field-effect transistors (ISFETs) are highly promising for lab-on-chip integration due to their excellent scalability, high sensitivity, and rapid response times. However, on-chip integration of reliable microscale reference electrodes, essential for ISFET operation in microfluidic systems, remains a significant challenge. This study presents a microfluidic pH meter that integrates silicon nanoribbon field-effect transistor (SiNRFET) sensors with on-chip microscale AgCl/Ag pseudo-reference electrodes (p-REs). The microscale p-REs, fabricated using CMOS-compatible processes and protected with a photoresist layer, demonstrated rapid stabilization and long-term stability. Moreover, the short distance between the integrated p-REs and the paired SiNRFET sensors within the microfluidic environment minimized streaming potential, ensuring measurement accuracy regardless of flow rate variations. In addition, applying an AC pulse gate bias effectively reduced ISFET signal drift caused by ion penetration into the pH-sensitive layer, enhancing the system's reliability for long-term monitoring. To showcase the platform’s biosensing capabilities, the microfluidic pH meter was finally used to monitor bacterial metabolism on-chip via measuring pH changes induced by metabolic activity with microliter-level samples. This work establishes a robust lab-on-chip biosensing platform, enabling real-time and long-term biosensing in microscale environments. • Integrated stable sub-10 μm AgCl/Ag pseudo reference electrodes, nanoscale ISFET sensors, and microfluidics for lab-on-chip biosensing application. • Minimized streaming potential effects by positioning the pseudo reference electrodes close to ISFET sensors. • Achieved significant reduction of ISFET drift by using an AC pulse gate bias. • Demonstrated on-chip bacterial metabolism monitoring using the integrated system.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-05-20
DOI
https://doi.org/10.1016/j.snb.2025.138000
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of AC bias-stabilized SiNRFETs with microscale Ag/AgCl pseudo-reference electrodes for lab-on-chip biosensing application

Zheqiang Xu, Paul Michael Solomon, Yingtao Yu, Zhen Zhang
1 citations
Sensors and Actuators B Chemical
Analytical Chemistry and Sensors
0.74
article

Integration of AC bias-stabilized SiNRFETs with microscale Ag/AgCl pseudo-reference electrodes for lab-on-chip biosensing application

Zheqiang Xu, Paul Michael Solomon, Yingtao Yu, Zhen Zhang
article en
1 citations

Abstract

Ion-sensitive field-effect transistors (ISFETs) are highly promising for lab-on-chip integration due to their excellent scalability, high sensitivity, and rapid response times. However, on-chip integration of reliable microscale reference electrodes, essential for ISFET operation in microfluidic systems, remains a significant challenge. This study presents a microfluidic pH meter that integrates silicon nanoribbon field-effect transistor (SiNRFET) sensors with on-chip microscale AgCl/Ag pseudo-reference electrodes (p-REs). The microscale p-REs, fabricated using CMOS-compatible processes and protected with a photoresist layer, demonstrated rapid stabilization and long-term stability. Moreover, the short distance between the integrated p-REs and the paired SiNRFET sensors within the microfluidic environment minimized streaming potential, ensuring measurement accuracy regardless of flow rate variations. In addition, applying an AC pulse gate bias effectively reduced ISFET signal drift caused by ion penetration into the pH-sensitive layer, enhancing the system's reliability for long-term monitoring. To showcase the platform’s biosensing capabilities, the microfluidic pH meter was finally used to monitor bacterial metabolism on-chip via measuring pH changes induced by metabolic activity with microliter-level samples. This work establishes a robust lab-on-chip biosensing platform, enabling real-time and long-term biosensing in microscale environments. • Integrated stable sub-10 μm AgCl/Ag pseudo reference electrodes, nanoscale ISFET sensors, and microfluidics for lab-on-chip biosensing application. • Minimized streaming potential effects by positioning the pseudo reference electrodes close to ISFET sensors. • Achieved significant reduction of ISFET drift by using an AC pulse gate bias. • Demonstrated on-chip bacterial metabolism monitoring using the integrated system.

Sensors and Actuators B ChemicalVol. 441
Uppsala University (SE), IBM Research - Thomas J. Watson Research Center (US)
Affordable and clean energy
Openalex Percentile: Top 33%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.