Analysis of Hyperbolic Cooling Tower Across Varying Earthquake Zones

This project uses STAAD to present the seismic analysis of a hyperbolic natural draft cooling tower located in Krishnapatnam Nellore district, Andhra Pradesh. As a vital component in industrial and power plant infrastructure, the structural stability of cooling towers under seismic loading is essential— particularly in regions like Krishnapatnam, which lies in Seismic Zone III as per IS 1893:2002. A tower model with realistic dimensions and material properties was analyzed under seismic forces corresponding to Zones II, III, IV, and V. The comparative study highlights the tower's behaviour under varying seismic intensities and evaluates the effect of zone-wise seismic forces on displacement, internal stresses, and support reactions. The findings support the need for zone-specific design modifications to improve seismic resilience. The study underscores the role of STAAD.Pro is an effective tool for evaluating tall, shell-type structures in earthquake-prone areas. Keywords: Hyperbolic Cooling Tower, Seismic Analysis, Equivalent Static Method, Shell structures, Displacement, Base shear, Principal stress, Plate moments, Plate stresses.

Authors

Publication Details

Journal
INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT
Published
2025-05-19
DOI
https://doi.org/10.55041/ijsrem48179
Primary Topic
Solar Energy Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Hyperbolic Cooling Tower Across Varying Earthquake Zones

Sofia Banu, Jayendra Kumar, T. SREEVALLI KAMESWARI, B RAVI et al.
INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT
Solar Energy Systems and Technologies
article

Analysis of Hyperbolic Cooling Tower Across Varying Earthquake Zones

Sofia Banu, Jayendra Kumar, T. SREEVALLI KAMESWARI, B RAVI, SK MEHARAJUNNISA, S SOWMYA
article en

Abstract

This project uses STAAD to present the seismic analysis of a hyperbolic natural draft cooling tower located in Krishnapatnam Nellore district, Andhra Pradesh. As a vital component in industrial and power plant infrastructure, the structural stability of cooling towers under seismic loading is essential— particularly in regions like Krishnapatnam, which lies in Seismic Zone III as per IS 1893:2002. A tower model with realistic dimensions and material properties was analyzed under seismic forces corresponding to Zones II, III, IV, and V. The comparative study highlights the tower's behaviour under varying seismic intensities and evaluates the effect of zone-wise seismic forces on displacement, internal stresses, and support reactions. The findings support the need for zone-specific design modifications to improve seismic resilience. The study underscores the role of STAAD.Pro is an effective tool for evaluating tall, shell-type structures in earthquake-prone areas. Keywords: Hyperbolic Cooling Tower, Seismic Analysis, Equivalent Static Method, Shell structures, Displacement, Base shear, Principal stress, Plate moments, Plate stresses.

INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENTVol. 09(05)
Openalex Percentile: Top 89%
Solar Energy Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.