An Aquatic Treadmill Alters Lower Limb Walking Dynamics in Typically Developing Children and Children with Cerebral Palsy

This block-randomized crossover study investigated how a speed-modulated aquatic treadmill (AT) impacts the walking biomechanics of pediatric gait. Eight cerebral palsy (CP) and fifteen typically developing (TD) children walked at normal, slow, and fast treadmill speeds in AT and dry treadmill (DT) conditions. The joint angles of participants were calculated from inertial measurement units to derive sample entropy (SE) measures that quantified the regularity or complexity of motion. A hierarchical statistical model revealed that the CP group had lower SE values for the hip, knee, and ankle joints in the AT and at slower than faster treadmill speeds. Only the SE values of the knee and ankle joints were impacted for the TD group. The lower SE values suggest improved regularity for participants at slower speeds and in the AT environment. This study highlights the potential of AT to improve the walking biomechanics of children with CP in acute exposure, but further work is needed to investigate the AT condition as a gait rehabilitation environment.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-05-20
DOI
https://doi.org/10.3390/s25103220
Primary Topic
Cerebral Palsy and Movement Disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Aquatic Treadmill Alters Lower Limb Walking Dynamics in Typically Developing Children and Children with Cerebral Palsy

Brian A. Knarr, Joseph W. Harrington, Aaron D. Likens, Oluwaseye Odanye et al.
Sensors
Cerebral Palsy and Movement Disorders
article

An Aquatic Treadmill Alters Lower Limb Walking Dynamics in Typically Developing Children and Children with Cerebral Palsy

Brian A. Knarr, Joseph W. Harrington, Aaron D. Likens, Oluwaseye Odanye, David C. Kingston
article en

Abstract

This block-randomized crossover study investigated how a speed-modulated aquatic treadmill (AT) impacts the walking biomechanics of pediatric gait. Eight cerebral palsy (CP) and fifteen typically developing (TD) children walked at normal, slow, and fast treadmill speeds in AT and dry treadmill (DT) conditions. The joint angles of participants were calculated from inertial measurement units to derive sample entropy (SE) measures that quantified the regularity or complexity of motion. A hierarchical statistical model revealed that the CP group had lower SE values for the hip, knee, and ankle joints in the AT and at slower than faster treadmill speeds. Only the SE values of the knee and ankle joints were impacted for the TD group. The lower SE values suggest improved regularity for participants at slower speeds and in the AT environment. This study highlights the potential of AT to improve the walking biomechanics of children with CP in acute exposure, but further work is needed to investigate the AT condition as a gait rehabilitation environment.

SensorsVol. 25(10)
University of Nebraska at Omaha (US)
National Institutes of Health
Openalex Percentile: Top 86%
Cerebral Palsy and Movement Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Aquatic Treadmill Alters Lower Limb Walking Dynamics in Typically Developing Children and Children with Cerebral Palsy — Brian A. Knarr, Joseph W. Harrington, et al. · Sensors (2025) | TGRS Research Map | TGRS