Microcontroller-Based Implementation of the DRT for Bioimpedance Spectroscopy

Bio-Impedance Spectroscopy (BIS) is a non-invasive method for characterizing biological systems. Converting impedance spectra into the distribution of relaxation times (DRT) allows the separation of overlapping effects without relying on equivalent circuits as impedance models. This transformation significantly reduces signal processing time from several seconds to milliseconds. Therefore, there is a significant need for embedded solutions that implement DRT in microcontroller-based systems. Following a detailed evaluation of various methodologies, NNLS combined with Tikhonov regularization was selected for its ability to achieve an 83.33% reduction in execution time. This paper presents a novel approach for implementing this optimized DRT extraction in STM32-based embedded systems. The novel implementation achieves processing times of 74 ms for a 101-frequency data set on the STM32 while utilizing only 2.69 kB of RAM. The system successfully extracts DRT peaks with different magnitudes and their relative relaxation times for 51-frequency and 101-frequency datasets. We demonstrate equivalent circuit parameter extraction with relative errors below 3.5%. This work establishes a foundation for portable BIS analysis, with potential applications in areas such as medical diagnostics, food state characterization, and plant monitoring.

Authors

Institutions

Publication Details

Published
2025-02-17
DOI
https://doi.org/10.1109/ssd64182.2025.10989846
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microcontroller-Based Implementation of the DRT for Bioimpedance Spectroscopy

Cherif Ouni, Salwa Sahnoun, Ahmed Fakhfakh, Olfa Kanoun et al.
Electrical and Bioimpedance Tomography
article

Microcontroller-Based Implementation of the DRT for Bioimpedance Spectroscopy

Cherif Ouni, Salwa Sahnoun, Ahmed Fakhfakh, Olfa Kanoun, Ahmed Yahia Kallel, Nabil Derbel, A. Trabelsi, N. Ammar
article en

Abstract

Bio-Impedance Spectroscopy (BIS) is a non-invasive method for characterizing biological systems. Converting impedance spectra into the distribution of relaxation times (DRT) allows the separation of overlapping effects without relying on equivalent circuits as impedance models. This transformation significantly reduces signal processing time from several seconds to milliseconds. Therefore, there is a significant need for embedded solutions that implement DRT in microcontroller-based systems. Following a detailed evaluation of various methodologies, NNLS combined with Tikhonov regularization was selected for its ability to achieve an 83.33% reduction in execution time. This paper presents a novel approach for implementing this optimized DRT extraction in STM32-based embedded systems. The novel implementation achieves processing times of 74 ms for a 101-frequency data set on the STM32 while utilizing only 2.69 kB of RAM. The system successfully extracts DRT peaks with different magnitudes and their relative relaxation times for 51-frequency and 101-frequency datasets. We demonstrate equivalent circuit parameter extraction with relative errors below 3.5%. This work establishes a foundation for portable BIS analysis, with potential applications in areas such as medical diagnostics, food state characterization, and plant monitoring.

Chemnitz University of Technology (DE), Digital Research Centre of Sfax (TN)
Affordable and clean energy
Openalex Percentile: Top 91%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microcontroller-Based Implementation of the DRT for Bioimpedance Spectroscopy — Cherif Ouni, Salwa Sahnoun, et al. · (2025) | TGRS Research Map | TGRS