UltraLightSqueezeNet: A Deep Learning Architecture for Malaria Classification With Up to 54× Fewer Trainable Parameters for Resource Constrained Devices

Lightweight deep learning approaches for malaria detection have gained attention for their potential to enhance diagnostics in resource constrained environments. For our study, we selected SqueezeNet1.1 as it is one of the most popular lightweight architectures. SqueezeNet1.1 is a later version of SqueezeNet1.0 and is 2.4 times more computationally efficient than the original model. We proposed and implemented three ultra-lightweight architecture variants to SqueezeNet1.1 architecture, namely Variant 1 (one fire module), Variant 2 (two fire modules), and Variant 3 (four fire modules), which are even more compact than SqueezeNetV1.1 (eight fire modules). These models were implemented to evaluate the best performing variant that achieves superior computational efficiency without sacrificing accuracy in malaria blood cell classification. The models were trained and evaluated using the NIH Malaria dataset. We assessed each model's performance based on metrics including accuracy, recall, precision, F1-score, and Area Under the Curve (AUC). The results show that the SqueezeNet1.1 model achieves the highest performance across all metrics, with a classification accuracy of 97.12%. Variant 3 (four fire modules) offers a competitive alternative, delivering almost identical results (accuracy 96.55%) with a 6x reduction in computational overhead compared to SqueezeNet1.1. Variant 2 and Variant 1 perform slightly lower than Variant 3, with Variant 2 (two fire modules) reducing computational overhead by 28x and Variant 1 (one fire module) achieving a 54x reduction in trainable parameters compared to SqueezeNet1.1. These findings demonstrate that our SqueezeNet1.1 architecture variants provide a flexible approach to malaria detection, enabling the selection of a variant that balances resource constraints and performance.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3571696
Citations
7
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
8.93
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

UltraLightSqueezeNet: A Deep Learning Architecture for Malaria Classification With Up to 54× Fewer Trainable Parameters for Resource Constrained Devices

Shanthi Karpurapu, Sravanthy Myneni, Unnati Nettur, Likhit Sagar Gajja et al.
7 citations
IEEE Access
Digital Imaging for Blood Diseases
8.93
article

UltraLightSqueezeNet: A Deep Learning Architecture for Malaria Classification With Up to 54× Fewer Trainable Parameters for Resource Constrained Devices

Shanthi Karpurapu, Sravanthy Myneni, Unnati Nettur, Likhit Sagar Gajja, Suresh Babu Nettur, Akhil Dusi, Lalithya Posham
article en
7 citations

Abstract

Lightweight deep learning approaches for malaria detection have gained attention for their potential to enhance diagnostics in resource constrained environments. For our study, we selected SqueezeNet1.1 as it is one of the most popular lightweight architectures. SqueezeNet1.1 is a later version of SqueezeNet1.0 and is 2.4 times more computationally efficient than the original model. We proposed and implemented three ultra-lightweight architecture variants to SqueezeNet1.1 architecture, namely Variant 1 (one fire module), Variant 2 (two fire modules), and Variant 3 (four fire modules), which are even more compact than SqueezeNetV1.1 (eight fire modules). These models were implemented to evaluate the best performing variant that achieves superior computational efficiency without sacrificing accuracy in malaria blood cell classification. The models were trained and evaluated using the NIH Malaria dataset. We assessed each model's performance based on metrics including accuracy, recall, precision, F1-score, and Area Under the Curve (AUC). The results show that the SqueezeNet1.1 model achieves the highest performance across all metrics, with a classification accuracy of 97.12%. Variant 3 (four fire modules) offers a competitive alternative, delivering almost identical results (accuracy 96.55%) with a 6x reduction in computational overhead compared to SqueezeNet1.1. Variant 2 and Variant 1 perform slightly lower than Variant 3, with Variant 2 (two fire modules) reducing computational overhead by 28x and Variant 1 (one fire module) achieving a 54x reduction in trainable parameters compared to SqueezeNet1.1. These findings demonstrate that our SqueezeNet1.1 architecture variants provide a flexible approach to malaria detection, enabling the selection of a variant that balances resource constraints and performance.

IEEE AccessVol. 13
Indiana Institute of Technology (US), BML Munjal University (IN), Nanjing Medical University (CN), Virginia Tech (US)
Zero hunger
Openalex Percentile: Top 2%
Digital Imaging for Blood Diseases
8.93
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.