Electroactive Flexible Sensor for Selective L-Ascorbic Acid Detection Using Polyaniline-Decorated Phosphotungstic Acid/Copper Composite

In this study, we spotlight a flexible stainless steel (FSS)- based hybrid electrode with phosphotungstic acid-copper-embedded poly(aniline) (FSS/PANI/PTA/Cu) composite for the efficient detection of L- ascorbic acid (AA). Single pot electrodeposition has been engaged in fabricating PANI/PTA/Cu composite on FSS via cyclic voltammetry(CV). The successful composite fabrication has been authenticated through physicochemical characterization, including its structural geometry, surface morphology, and molecular vibrational properties, which were analyzed through X-ray crystallography (XRD), field emission scanning electron microscopy (FESEM), infrared spectroscopy (FTIR) and UV-Vis spectrophotometers. The electrochemical sensing performances were examined using CV and chronoamperometric analysis (CA). The flexible sensor measured a sensitivity of 3.79 mA/mM with a detection limit (LOD) of 7.9 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mu$</tex-math></inline-formula>M for AA. This performance results from the combined synergetic action of PANI, PTA, and Cu, which enabled efficient ionic diffusion and seamless electron transfer through a high density of accessible electroactive sites. Additionally, the flexible sensor electrode exhibited remarkable selectivity for AA, with negligible interference from co-existing species, highlighting its potential for healthcare diagnostic applications in near future.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2025-05-20
DOI
https://doi.org/10.1109/lsens.2025.3571539
Citations
1
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electroactive Flexible Sensor for Selective L-Ascorbic Acid Detection Using Polyaniline-Decorated Phosphotungstic Acid/Copper Composite

Muthusankar Eswaran, S. Archana, Ragupathy Dhanusuraman, Sethu Selvaraj
1 citations
IEEE Sensors Letters
Conducting polymers and applications
0.61
article

Electroactive Flexible Sensor for Selective L-Ascorbic Acid Detection Using Polyaniline-Decorated Phosphotungstic Acid/Copper Composite

Muthusankar Eswaran, S. Archana, Ragupathy Dhanusuraman, Sethu Selvaraj
article en
1 citations

Abstract

In this study, we spotlight a flexible stainless steel (FSS)- based hybrid electrode with phosphotungstic acid-copper-embedded poly(aniline) (FSS/PANI/PTA/Cu) composite for the efficient detection of L- ascorbic acid (AA). Single pot electrodeposition has been engaged in fabricating PANI/PTA/Cu composite on FSS via cyclic voltammetry(CV). The successful composite fabrication has been authenticated through physicochemical characterization, including its structural geometry, surface morphology, and molecular vibrational properties, which were analyzed through X-ray crystallography (XRD), field emission scanning electron microscopy (FESEM), infrared spectroscopy (FTIR) and UV-Vis spectrophotometers. The electrochemical sensing performances were examined using CV and chronoamperometric analysis (CA). The flexible sensor measured a sensitivity of 3.79 mA/mM with a detection limit (LOD) of 7.9 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mu$</tex-math></inline-formula>M for AA. This performance results from the combined synergetic action of PANI, PTA, and Cu, which enabled efficient ionic diffusion and seamless electron transfer through a high density of accessible electroactive sites. Additionally, the flexible sensor electrode exhibited remarkable selectivity for AA, with negligible interference from co-existing species, highlighting its potential for healthcare diagnostic applications in near future.

IEEE Sensors LettersVol. 9(7)
Kaohsiung Medical University (TW), Pondicherry University (IN), Kerala University of Health Sciences (IN)
Openalex Percentile: Top 36%
Conducting polymers and applications
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.