Experimentally Driven Numerical Model of Carbon/Polyaniline-Based Glucose Monitoring Sensors: An Evaluation Using a New Figure of Merit

This study presents an experimentally driven numerical model for evaluating carbon/polyaniline (PANI)-based glucose monitoring sensors, focusing on innovative configurations using graphene-PANI and carbon nanotube (CNT)-PANI composites. We performed a thorough analysis of the morphological, electrophysical, and electrical properties of these materials, ultimately leading to the extraction of key electrical parameters for integration into a finite element model (FEM). This model simulates the entire sensor, enabling the estimation of critical performance metrics such as sensitivity, limit of detection (LOD), linearity, and power consumption. Our findings demonstrate that the CNT-PANI configuration significantly outperforms the laser induced graphene (LIG)-PANI electrode, achieving a figure of merit (FOM) of 0.99 compared to 0.62, thanks to its superior electrical conductivity and high surface area, which facilitates enhanced charge transfer and electrochemical reactions. The optimized sensor configurations reveal optimal parameters for LIG-PANI and CNT-PANI, underscoring the trade-offs between conductivity and overall sensor performance. Notably, the CNT-PANI composite exhibits the highest sensitivity of 2778 μA mM<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-2</sup> and the lowest LOD of 0.09 μM, making it a promising candidate for glucose detection in clinical applications. This work highlights the importance of power consumption in sensor design, with all configurations operating at 0.232 mW, and sets a new benchmark for future glucose monitoring technologies. Finally, the study illustrated a clinical investigation to verify the selectivity and sensitivity of PANI towards various molar concentrations of glucose.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-05-20
DOI
https://doi.org/10.1109/jsen.2025.3570069
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimentally Driven Numerical Model of Carbon/Polyaniline-Based Glucose Monitoring Sensors: An Evaluation Using a New Figure of Merit

Sameh O. Abdellatif, Amira Ali, Kyrillos K. Selim, Ziad Khalifa
1 citations
IEEE Sensors Journal
Electrochemical sensors and biosensors
0.73
article

Experimentally Driven Numerical Model of Carbon/Polyaniline-Based Glucose Monitoring Sensors: An Evaluation Using a New Figure of Merit

Sameh O. Abdellatif, Amira Ali, Kyrillos K. Selim, Ziad Khalifa
article en
1 citations

Abstract

This study presents an experimentally driven numerical model for evaluating carbon/polyaniline (PANI)-based glucose monitoring sensors, focusing on innovative configurations using graphene-PANI and carbon nanotube (CNT)-PANI composites. We performed a thorough analysis of the morphological, electrophysical, and electrical properties of these materials, ultimately leading to the extraction of key electrical parameters for integration into a finite element model (FEM). This model simulates the entire sensor, enabling the estimation of critical performance metrics such as sensitivity, limit of detection (LOD), linearity, and power consumption. Our findings demonstrate that the CNT-PANI configuration significantly outperforms the laser induced graphene (LIG)-PANI electrode, achieving a figure of merit (FOM) of 0.99 compared to 0.62, thanks to its superior electrical conductivity and high surface area, which facilitates enhanced charge transfer and electrochemical reactions. The optimized sensor configurations reveal optimal parameters for LIG-PANI and CNT-PANI, underscoring the trade-offs between conductivity and overall sensor performance. Notably, the CNT-PANI composite exhibits the highest sensitivity of 2778 μA mM<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-2</sup> and the lowest LOD of 0.09 μM, making it a promising candidate for glucose detection in clinical applications. This work highlights the importance of power consumption in sensor design, with all configurations operating at 0.232 mW, and sets a new benchmark for future glucose monitoring technologies. Finally, the study illustrated a clinical investigation to verify the selectivity and sensitivity of PANI towards various molar concentrations of glucose.

IEEE Sensors JournalVol. 25(13)
British University in Egypt (EG), El Shorouk Academy (EG), Helwan University (EG)
Openalex Percentile: Top 28%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.