Reliability Simulation and Analysis of a 340 GHz Traveling Wave Tube

With the rapid development of terahertz (0.1–10 THz) technology in biomedical sensing, space communication, and security inspection fields, the demands for high-reliability THz radiation sources are becoming increasingly urgent. As a key vacuum electronic device, the reliability of traveling-wave tube (TWT) is significantly affected by temperature and external vibration environment. In the present work, a systematic multiphysics coupling reliability analysis method for 340-GHz space TWT is proposed for the first time, covering thermodynamic, modal, and vibration simulations, and verified through extreme environmental experiments. Based on finite element analysis (FEA), the study shows the following key results: 1) under dynamic conditions, the highest temperature zone (212 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∘</sup>C) is observed at the end of multistage depressed collector (MDC) and the heat conduction path and substrate heat dissipation design effectively suppress the risk of temperature rise; 2) modal analysis shows that the root of the input/output window is a vibration-sensitive area (the first natural frequency of 1729.6 Hz) and external resonance should be avoided; 3) a safety matrix (SM) is introduced to evaluate vibration reliability, the ratio of equivalent stress (23.4 MPa) to material allowable stress under random vibration is SM = 2.7, which meets the safety threshold; and 4) in the -55 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∘</sup>C static low-temperature experiment, the measured temperature of the slow wave structure (SWS) had an error of about 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∘</sup>C compared to the simulations, which verified the accuracy of the multiphysics field coupling model. This article innovatively combines electromagnetic thermal force multifield simulation and extreme environment experiments to clarify the weak links and optimization directions of TWT in the THz band, providing important references for the design and engineering application of high-reliability vacuum electronic devices.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Electron Devices
Published
2025-05-20
DOI
https://doi.org/10.1109/ted.2025.3564262
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability Simulation and Analysis of a 340 GHz Traveling Wave Tube

Gongao Xia, Jinshu Wang, Zhihao Jin, Jianwei Zhong et al.
1 links
IEEE Transactions on Electron Devices
Engineering Applied Research
article

Reliability Simulation and Analysis of a 340 GHz Traveling Wave Tube

Gongao Xia, Jinshu Wang, Zhihao Jin, Jianwei Zhong, Yunfei Yang, Xiangpeng Liu
article en

Abstract

With the rapid development of terahertz (0.1–10 THz) technology in biomedical sensing, space communication, and security inspection fields, the demands for high-reliability THz radiation sources are becoming increasingly urgent. As a key vacuum electronic device, the reliability of traveling-wave tube (TWT) is significantly affected by temperature and external vibration environment. In the present work, a systematic multiphysics coupling reliability analysis method for 340-GHz space TWT is proposed for the first time, covering thermodynamic, modal, and vibration simulations, and verified through extreme environmental experiments. Based on finite element analysis (FEA), the study shows the following key results: 1) under dynamic conditions, the highest temperature zone (212 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∘</sup>C) is observed at the end of multistage depressed collector (MDC) and the heat conduction path and substrate heat dissipation design effectively suppress the risk of temperature rise; 2) modal analysis shows that the root of the input/output window is a vibration-sensitive area (the first natural frequency of 1729.6 Hz) and external resonance should be avoided; 3) a safety matrix (SM) is introduced to evaluate vibration reliability, the ratio of equivalent stress (23.4 MPa) to material allowable stress under random vibration is SM = 2.7, which meets the safety threshold; and 4) in the -55 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∘</sup>C static low-temperature experiment, the measured temperature of the slow wave structure (SWS) had an error of about 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∘</sup>C compared to the simulations, which verified the accuracy of the multiphysics field coupling model. This article innovatively combines electromagnetic thermal force multifield simulation and extreme environment experiments to clarify the weak links and optimization directions of TWT in the THz band, providing important references for the design and engineering application of high-reliability vacuum electronic devices.

IEEE Transactions on Electron DevicesVol. 72(6)
Chinese Academy of Sciences (CN), Beijing University of Technology (CN), Aerospace Information Research Institute (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 89%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.