Impedance Modeling for Line-Frequency Rectified Constant-Power Loads

Constant-power loads (CPLs) represent a growing presence on utility grids and microgrids. These power electronic loads are frequently configured as rectified loads operating from an ac input to produce a controlled dc output at a constant power level. This constant-power demand creates a well-known incremental negative input impedance that "fights" changes in grid voltage by demanding opposing changes in input current to maintain constant power operation for a load. Rectified CPLs can, therefore, create instabilities with relatively unique perturbations in the envelope of ac-side current and voltage. A system’s envelope response, characterized by the envelope impedance, has allowed for the application of traditional stability analysis techniques to rectified CPLs where complex nonlinear dynamics prevent the use of, e.g., small-signal approximations. This paper presents clear and experimentally useful definitions for envelope impedance, explains the limitations of traditional single-frequency perturbation stability analysis for rectified CPLs, develops new techniques for estimating rectified CPL input impedance using a double Fourier integral method, and demonstrates these techniques with both simulations and experimental results.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3572006
Citations
3
Primary Topic
Electromagnetic Compatibility and Noise Suppression
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impedance Modeling for Line-Frequency Rectified Constant-Power Loads

Eric A. Ponce, Steven B. Leeb
3 citations
IEEE Access
Electromagnetic Compatibility and Noise Suppression
2.19
article

Impedance Modeling for Line-Frequency Rectified Constant-Power Loads

Eric A. Ponce, Steven B. Leeb
article en
3 citations

Abstract

Constant-power loads (CPLs) represent a growing presence on utility grids and microgrids. These power electronic loads are frequently configured as rectified loads operating from an ac input to produce a controlled dc output at a constant power level. This constant-power demand creates a well-known incremental negative input impedance that "fights" changes in grid voltage by demanding opposing changes in input current to maintain constant power operation for a load. Rectified CPLs can, therefore, create instabilities with relatively unique perturbations in the envelope of ac-side current and voltage. A system’s envelope response, characterized by the envelope impedance, has allowed for the application of traditional stability analysis techniques to rectified CPLs where complex nonlinear dynamics prevent the use of, e.g., small-signal approximations. This paper presents clear and experimentally useful definitions for envelope impedance, explains the limitations of traditional single-frequency perturbation stability analysis for rectified CPLs, develops new techniques for estimating rectified CPL input impedance using a double Fourier integral method, and demonstrates these techniques with both simulations and experimental results.

IEEE AccessVol. 13
Massachusetts Institute of Technology (US)
Office of Naval Research
Affordable and clean energy
Openalex Percentile: Top 12%
Electromagnetic Compatibility and Noise Suppression
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.