A Microwave Sensor Based on Concentric Split-Ring Resonators for Blood Urea Detection: A Novel Tool for Chronic Kidney Disease Diagnosis

Chronic kidney disease (CKD) affects millions of people worldwide, making early diagnosis critical for effective management and healthcare cost reduction. Monitoring blood urea levels is essential for this purpose. In this paper, we present a microwave sensor capable of detecting urea concentrations within the clinical range required for CKD diagnosis, a sensitivity not achieved by previous microwave (MW) based approaches. The proposed device operates without reagents or enzymes, requires no specialized personnel and offers an extended lifespan, ease of use, and sensitivity comparable to conventional optical sensors. Our work consists of two main steps. First, we conducted a dielectric characterization of artificial blood plasma (ABPS) and urea-enriched ABPS (ABPSU, 320 mg/dL) over a frequency range of 500 MHz to 10 GHz. The results revealed that the most significant differentiation between samples occurs at low frequencies, particularly in the loss tangent rather than in the real part of the dielectric constant, thereby identifying the optimal frequency range for sensor design. In the second step, we designed a double concentric circular split-ring resonator (DCCSRR) on a 49 mm × 45 mm Rogers 5880™ substrate. A dedicated optimization protocol enhanced both the resonance peak amplitude and the quality factor of the sensor’s fundamental mode. After fabrication, the DCCSRR was tested for urea concentrations ranging from 10 to 320 mg/dL, exhibiting measurable variations in S21 (dB) and frequency shifts around 575 MHz. This study establishes the first microwave sensor operating within the urea concentration range necessary for CKD diagnosis, paving the way for practical microwave-based urea monitoring.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-05-20
DOI
https://doi.org/10.1109/jsen.2025.3570067
Citations
2
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Microwave Sensor Based on Concentric Split-Ring Resonators for Blood Urea Detection: A Novel Tool for Chronic Kidney Disease Diagnosis

Mateus I. O. Souza, Vinícius M. Pepino, Natália M. Santos, Ben‐Hur V. Borges et al.
2 citations
IEEE Sensors Journal
Microwave and Dielectric Measurement Techniques
1.46
article

A Microwave Sensor Based on Concentric Split-Ring Resonators for Blood Urea Detection: A Novel Tool for Chronic Kidney Disease Diagnosis

Mateus I. O. Souza, Vinícius M. Pepino, Natália M. Santos, Ben‐Hur V. Borges, Laudemir C. Varanda
article en
2 citations

Abstract

Chronic kidney disease (CKD) affects millions of people worldwide, making early diagnosis critical for effective management and healthcare cost reduction. Monitoring blood urea levels is essential for this purpose. In this paper, we present a microwave sensor capable of detecting urea concentrations within the clinical range required for CKD diagnosis, a sensitivity not achieved by previous microwave (MW) based approaches. The proposed device operates without reagents or enzymes, requires no specialized personnel and offers an extended lifespan, ease of use, and sensitivity comparable to conventional optical sensors. Our work consists of two main steps. First, we conducted a dielectric characterization of artificial blood plasma (ABPS) and urea-enriched ABPS (ABPSU, 320 mg/dL) over a frequency range of 500 MHz to 10 GHz. The results revealed that the most significant differentiation between samples occurs at low frequencies, particularly in the loss tangent rather than in the real part of the dielectric constant, thereby identifying the optimal frequency range for sensor design. In the second step, we designed a double concentric circular split-ring resonator (DCCSRR) on a 49 mm × 45 mm Rogers 5880™ substrate. A dedicated optimization protocol enhanced both the resonance peak amplitude and the quality factor of the sensor’s fundamental mode. After fabrication, the DCCSRR was tested for urea concentrations ranging from 10 to 320 mg/dL, exhibiting measurable variations in S21 (dB) and frequency shifts around 575 MHz. This study establishes the first microwave sensor operating within the urea concentration range necessary for CKD diagnosis, paving the way for practical microwave-based urea monitoring.

IEEE Sensors JournalVol. 25(13)
Universidade Federal de São Carlos (BR), Institute of Mathematics and Computer Science (MD)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico
Good health and well-being
Openalex Percentile: Top 17%
Microwave and Dielectric Measurement Techniques
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.