CT Image Quality Assessment Based on Denoising Auto-Encoder

Due to the restriction of lacking reference image, medical image evaluation is still a hot and challenging problem, in that we proposed a new evaluation strategy for CT images based on denoising auto-encoder (DAE). Firstly, pseudo-reference map of the CT image is obtained based on the DAE network, and then derived from the difference between the original CT and the new map, the global assessment of the CT can be achieved. An adaptive feature fusion module is added in the encoding process and we introduced a countermeasure network in the basic DAE network to reduce cross artifacts in the reconstructed image. In addition, we made up for the evaluation deviation caused by local artifacts by combining global and local results. Experiments on the CT dataset exhibit good result. The Pearson linear correlation coefficient (PLCC) of our method and learned perceptual image patch similarity (LPIPS) is 0. 905656, the Spearman rank correlation coefficient (SRCC) index is 0. 871139. The accuracy of binary classification based on real clinical data is 0. 947891, and the F1 score is 0. 956521.

Authors

Institutions

Publication Details

Published
2024-11-20
DOI
https://doi.org/10.1109/dsins64146.2024.10992084
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CT Image Quality Assessment Based on Denoising Auto-Encoder

Bo Peng, Yuxin Wang, Huilin Zheng
3 links
Advanced X-ray and CT Imaging
article

CT Image Quality Assessment Based on Denoising Auto-Encoder

Bo Peng, Yuxin Wang, Huilin Zheng
article en

Abstract

Due to the restriction of lacking reference image, medical image evaluation is still a hot and challenging problem, in that we proposed a new evaluation strategy for CT images based on denoising auto-encoder (DAE). Firstly, pseudo-reference map of the CT image is obtained based on the DAE network, and then derived from the difference between the original CT and the new map, the global assessment of the CT can be achieved. An adaptive feature fusion module is added in the encoding process and we introduced a countermeasure network in the basic DAE network to reduce cross artifacts in the reconstructed image. In addition, we made up for the evaluation deviation caused by local artifacts by combining global and local results. Experiments on the CT dataset exhibit good result. The Pearson linear correlation coefficient (PLCC) of our method and learned perceptual image patch similarity (LPIPS) is 0. 905656, the Spearman rank correlation coefficient (SRCC) index is 0. 871139. The accuracy of binary classification based on real clinical data is 0. 947891, and the F1 score is 0. 956521.

Southwest Jiaotong University (CN)
Climate action
Openalex Percentile: Top 74%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.