Power Imbalance Compensation of Droop-Based Distributed Control With Wireless Communication in Multi-Cell AC-DC Converters

This paper proposes an enhanced distributed control scheme with power imbalance compensation for an Input-ParallelOutput-Parallel (IPOP) AC-DC converter featuring a power imbalance compensator that incorporates non-instantaneous values. Power-sharing imbalances are a common issue in parallelconnected cell converters due to wiring resistance between the load and individual cells under conventional droop control. The proposed compensator, placed in the outer loop of the voltage and current feedback loops, effectively mitigates these imbalances. By leveraging non-instantaneous values, the control scheme accepts low-bandwidth communication, enabling the use of low-speed wireless modules and reducing the required signal lines, thus enhancing system flexibility. The experimental validation is conducted using a 7.2-kW prototype comprising six cells with integrated wireless communication modules. The results demonstrate that the proposed method reduces output current imbalance by up to 94% compared to conventional approaches.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industry Applications
Published
2025-05-20
DOI
https://doi.org/10.1109/tia.2025.3571830
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Imbalance Compensation of Droop-Based Distributed Control With Wireless Communication in Multi-Cell AC-DC Converters

Keita Ohata, Keisuke Kusaka, Hiroki Watanabe, J. Itoh et al.
IEEE Transactions on Industry Applications
Microgrid Control and Optimization
article

Power Imbalance Compensation of Droop-Based Distributed Control With Wireless Communication in Multi-Cell AC-DC Converters

Keita Ohata, Keisuke Kusaka, Hiroki Watanabe, J. Itoh, Masakazu Adachi
article en

Abstract

This paper proposes an enhanced distributed control scheme with power imbalance compensation for an Input-ParallelOutput-Parallel (IPOP) AC-DC converter featuring a power imbalance compensator that incorporates non-instantaneous values. Power-sharing imbalances are a common issue in parallelconnected cell converters due to wiring resistance between the load and individual cells under conventional droop control. The proposed compensator, placed in the outer loop of the voltage and current feedback loops, effectively mitigates these imbalances. By leveraging non-instantaneous values, the control scheme accepts low-bandwidth communication, enabling the use of low-speed wireless modules and reducing the required signal lines, thus enhancing system flexibility. The experimental validation is conducted using a 7.2-kW prototype comprising six cells with integrated wireless communication modules. The results demonstrate that the proposed method reduces output current imbalance by up to 94% compared to conventional approaches.

IEEE Transactions on Industry ApplicationsVol. 61(6)
Nagaoka University (JP)
Affordable and clean energy
Openalex Percentile: Top 88%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.