A Comprehensive Digital Calibration Method for Pipeline SAR ADCs Using Extended Kalman Filter

This paper presents a fully digital foreground calibration method for pipeline-SAR analog-to-digital converters (ADCs) using sine-fit based on the Extended Kalman Filter (EKF). The sine-fit technique provides a reference output, while an adaptive Least Mean Square (LMS) algorithm iteratively adjusts the reconstruction weights to correct mismatches and nonlinearities. The EKF significantly reduces hardware complexity by enabling real-time estimation without requiring extensive data storage. A modeled 12-bit pipeline-SAR ADC is used to evaluate the method's effectiveness. Simulation results demonstrate that the proposed calibration scheme improves the spurious-free dynamic range (SFDR) and signal-to-noise-and-distortion ratio (SNDR) by 33.6 dB and 18.8 dB, respectively.

Authors

Institutions

Publication Details

Journal
Integrated Circuits and Systems
Published
2025-05-20
DOI
https://doi.org/10.23919/ics.2025.3571821
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comprehensive Digital Calibration Method for Pipeline SAR ADCs Using Extended Kalman Filter

Fan Ye, Yuguo Xiang, Dayan Zhou
1 links
Integrated Circuits and Systems
Fault Detection and Control Systems
article

A Comprehensive Digital Calibration Method for Pipeline SAR ADCs Using Extended Kalman Filter

Fan Ye, Yuguo Xiang, Dayan Zhou
article en

Abstract

This paper presents a fully digital foreground calibration method for pipeline-SAR analog-to-digital converters (ADCs) using sine-fit based on the Extended Kalman Filter (EKF). The sine-fit technique provides a reference output, while an adaptive Least Mean Square (LMS) algorithm iteratively adjusts the reconstruction weights to correct mismatches and nonlinearities. The EKF significantly reduces hardware complexity by enabling real-time estimation without requiring extensive data storage. A modeled 12-bit pipeline-SAR ADC is used to evaluate the method's effectiveness. Simulation results demonstrate that the proposed calibration scheme improves the spurious-free dynamic range (SFDR) and signal-to-noise-and-distortion ratio (SNDR) by 33.6 dB and 18.8 dB, respectively.

Integrated Circuits and SystemsVol. 2(3)
Fudan University (CN)
Openalex Percentile: Top 88%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.