Hybrid GOA and PSO optimization for load frequency control in renewable multi source dual area power systems

The integration of unconventional power sources, such as solar, wind, and electric vehicles (EVs), into electrical power grids poses significant challenges in maintaining frequency stability and consistent tie-line power flows. These fluctuations can compromise the reliability and quality of power delivered to end-users. To address these challenges, this paper proposes a novel Proportional-Integral-Derivative (PID) controller optimized using a hybrid Grasshopper Optimization Algorithm-Particle Swarm Optimization (GOA-PSO) approach. Unlike conventional tuning methods, the proposed GOA-PSO hybridization leverages the exploratory strengths of GOA and the exploitative capabilities of PSO, resulting in an optimized control strategy that significantly enhances load frequency control (LFC) performance. This study is among the first to integrate a fuzzy-based MPPT PV system, a P&O MPPT-controlled PMSG-based wind energy system, and EVs within a single-area multi-source energy network while simultaneously addressing a dual-area interconnected power system (IPS). The GOA-PSO-PID controller is fine-tuned using the Integral Time Absolute Error (ITAE) as a fitness function to enhance control efficiency. The controller's effectiveness is evaluated across two distinct cases: (1) a single-area system integrating thermal, solar, wind, and EV resources, and (2) a two-area thermal tie-line interconnected power system. Comparative studies across various operational scenarios, including extensive parameter variations (± 40%) and load fluctuations, demonstrate the superior performance of the GOA-PSO-PID controller over the conventional PSO-PID approach. The GOA-PSO-PID achieves a 79.95% reduction in overshoot, a 92.78% reduction in undershoot, and a 98.91% improvement in settling time in the single-area system. Similarly, in the dual-area IPS, it provides a 76.73% reduction in overshoot, an 87.62% reduction in undershoot, and a 75.68% improvement in rise time. These findings highlight the robustness and adaptability of the GOA-PSO-PID controller in handling highly fluctuating renewable-dominated power networks, making it a reliable solution for future smart grids.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-20
DOI
https://doi.org/10.1038/s41598-025-01481-6
Citations
7
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
5.11
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid GOA and PSO optimization for load frequency control in renewable multi source dual area power systems

Fayez F. M. El-Sousy, Abdul Khalique Junejo, Ibtisam Naveed, Rizwan Aziz Siddiqui et al.
7 citations
Scientific Reports
Frequency Control in Power Systems
5.11
article

Hybrid GOA and PSO optimization for load frequency control in renewable multi source dual area power systems

Fayez F. M. El-Sousy, Abdul Khalique Junejo, Ibtisam Naveed, Rizwan Aziz Siddiqui, Zhigang Lu, Muhammad Zubair Yameen
article en
7 citations

Abstract

The integration of unconventional power sources, such as solar, wind, and electric vehicles (EVs), into electrical power grids poses significant challenges in maintaining frequency stability and consistent tie-line power flows. These fluctuations can compromise the reliability and quality of power delivered to end-users. To address these challenges, this paper proposes a novel Proportional-Integral-Derivative (PID) controller optimized using a hybrid Grasshopper Optimization Algorithm-Particle Swarm Optimization (GOA-PSO) approach. Unlike conventional tuning methods, the proposed GOA-PSO hybridization leverages the exploratory strengths of GOA and the exploitative capabilities of PSO, resulting in an optimized control strategy that significantly enhances load frequency control (LFC) performance. This study is among the first to integrate a fuzzy-based MPPT PV system, a P&O MPPT-controlled PMSG-based wind energy system, and EVs within a single-area multi-source energy network while simultaneously addressing a dual-area interconnected power system (IPS). The GOA-PSO-PID controller is fine-tuned using the Integral Time Absolute Error (ITAE) as a fitness function to enhance control efficiency. The controller's effectiveness is evaluated across two distinct cases: (1) a single-area system integrating thermal, solar, wind, and EV resources, and (2) a two-area thermal tie-line interconnected power system. Comparative studies across various operational scenarios, including extensive parameter variations (± 40%) and load fluctuations, demonstrate the superior performance of the GOA-PSO-PID controller over the conventional PSO-PID approach. The GOA-PSO-PID achieves a 79.95% reduction in overshoot, a 92.78% reduction in undershoot, and a 98.91% improvement in settling time in the single-area system. Similarly, in the dual-area IPS, it provides a 76.73% reduction in overshoot, an 87.62% reduction in undershoot, and a 75.68% improvement in rise time. These findings highlight the robustness and adaptability of the GOA-PSO-PID controller in handling highly fluctuating renewable-dominated power networks, making it a reliable solution for future smart grids.

Scientific ReportsVol. 15(1)
Prince Sattam Bin Abdulaziz University (SA), Yanshan University (CN), Quaid-e-Awam University of Engineering, Science and Technology (PK), Southeast University (CN)
Affordable and clean energy
Openalex Percentile: Top 5%
Frequency Control in Power Systems
5.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.