Algorithm for Determination of Arrival Time of Signals from the Liquid Xenon Calorimeter of CMD-3 Detector

In CMD-3 detector the n– $$\bar {n}$$ pair production events can be detected only by the calorimeters where a large energy deposition from antineutron annihilation occurs. For identification of such events it is necessary to determine the arrival time of the calorimeter signals with accuracy of several nanoseconds. Preliminary estimations have shown that the required time resolution can be obtained only basing on signals of the liquid‑xenon calorimeter. The shapes of the liquid‑xenon calorimeter’s output electric signals differ substantially from event to event, thus an additional error is added to the measured signal arrival time even when a constant‑fraction discriminator is used. For measuring the arrival time of the liquid‑xenon calorimeter’s signals a special digital signal processing algorithm has been developed which allows one to reduce the error of signal arrival time determination added by the difference of signals' shapes. In this paper the developed algorithm is described and the results obtained after optimization of this algorithm on the real events data are presented.

Authors

Institutions

Publication Details

Journal
Physics of Particles and Nuclei
Published
2025-04-01
DOI
https://doi.org/10.1134/s1063779624701399
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Algorithm for Determination of Arrival Time of Signals from the Liquid Xenon Calorimeter of CMD-3 Detector

L. B. Epshtein, Yu. V. Yudin, K. Mikhailov
Physics of Particles and Nuclei
Medical Imaging Techniques and Applications
article

Algorithm for Determination of Arrival Time of Signals from the Liquid Xenon Calorimeter of CMD-3 Detector

L. B. Epshtein, Yu. V. Yudin, K. Mikhailov
article en

Abstract

In CMD-3 detector the n– $$\bar {n}$$ pair production events can be detected only by the calorimeters where a large energy deposition from antineutron annihilation occurs. For identification of such events it is necessary to determine the arrival time of the calorimeter signals with accuracy of several nanoseconds. Preliminary estimations have shown that the required time resolution can be obtained only basing on signals of the liquid‑xenon calorimeter. The shapes of the liquid‑xenon calorimeter’s output electric signals differ substantially from event to event, thus an additional error is added to the measured signal arrival time even when a constant‑fraction discriminator is used. For measuring the arrival time of the liquid‑xenon calorimeter’s signals a special digital signal processing algorithm has been developed which allows one to reduce the error of signal arrival time determination added by the difference of signals' shapes. In this paper the developed algorithm is described and the results obtained after optimization of this algorithm on the real events data are presented.

Physics of Particles and NucleiVol. 56(2)
Novosibirsk State University (RU), Budker Institute of Nuclear Physics (RU), Novosibirsk State Technical University (RU)
Affordable and clean energy
Openalex Percentile: Top 83%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.