A Low-vibration Controller for the Series Elastic Tendon-driven Robots

Series elastic tendon-drive robots have been proposed intended for safe physical human-robot interaction. While the tendon elasticity enables a safe task execution under hand contact conditions, it poses overshoot and vibration problems in tasks without hand contact. In this paper, we install an electromagnetic brake in the pulley at the middle of the cable path, in order to stabilize the vibration. This method enables a wide range of viscosity changes, because the elements are arranged so that the brake force is directly transmitted to the arm. Moreover, redesign of the joint structure is unnecessary. The elastic tendon with brake can be modeled as a parallel viscoelastic element. We propose a sliding mode controller by using the electromagnetic brake. High-speed friction control by the electromagnetic brake allows an oscillation-free positioning controller. Unlike conventional sliding mode controllers, softness (low stiffness) of the controlled arm is not lost because high-gain position feedback is not used. Reachability condition of the sliding surface is expressed in terms of the equilibrium and target positions of the arm angles. Control results are demonstrated experimentally.

Authors

Institutions

Publication Details

Journal
Journal of the Robotics Society of Japan
Published
2025-01-01
DOI
https://doi.org/10.7210/jrsj.43.407
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Low-vibration Controller for the Series Elastic Tendon-driven Robots

Shuji Koyama, Kohei SUZUKI, Kazuhisa Mitobe, Atsushi Sekiya
Journal of the Robotics Society of Japan
Prosthetics and Rehabilitation Robotics
article

A Low-vibration Controller for the Series Elastic Tendon-driven Robots

Shuji Koyama, Kohei SUZUKI, Kazuhisa Mitobe, Atsushi Sekiya
article en

Abstract

Series elastic tendon-drive robots have been proposed intended for safe physical human-robot interaction. While the tendon elasticity enables a safe task execution under hand contact conditions, it poses overshoot and vibration problems in tasks without hand contact. In this paper, we install an electromagnetic brake in the pulley at the middle of the cable path, in order to stabilize the vibration. This method enables a wide range of viscosity changes, because the elements are arranged so that the brake force is directly transmitted to the arm. Moreover, redesign of the joint structure is unnecessary. The elastic tendon with brake can be modeled as a parallel viscoelastic element. We propose a sliding mode controller by using the electromagnetic brake. High-speed friction control by the electromagnetic brake allows an oscillation-free positioning controller. Unlike conventional sliding mode controllers, softness (low stiffness) of the controlled arm is not lost because high-gain position feedback is not used. Reachability condition of the sliding surface is expressed in terms of the equilibrium and target positions of the arm angles. Control results are demonstrated experimentally.

Journal of the Robotics Society of JapanVol. 43(4)
Yamagata University (JP)
Affordable and clean energy
Openalex Percentile: Top 90%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.