Integrating activity-based transport and building occupancy models for campus-scale energy management

Arrivals and departures lie at the intersection of travel and building occupancy behaviours which dominate the landscape of energy demand in urban areas. Although transport and building systems are clearly linked, existing studies rarely consider the interactions between these systems in their modelling frameworks, thus restricting the policy-relevant scenarios that can be tested. This paper contributes to the field of data-driven energy modelling by proposing a flexible framework to integrate the modelling of travel and building occupancy behaviours, in which a travel simulator is coupled with a building occupancy model through a proposed mesoscopic link. The framework is operationalised in the context of the South Kensington Campus, Imperial College London, using the UK Time Use Survey data and Wi-Fi traceable logs. Implementing the framework for a hypothetical transport incident (i.e. sudden closure of the nearest underground station) generates people’s occupancy and circulation patterns across buildings, thus providing actionable insights for district-level smart grid planning and management. From a district planning perspective, occupancy schedules and dynamics in closed buildings are sensitive to incidents, whereas open and shared buildings are relatively stable. This finding indicates the need for flexible energy controls and smart grids with energy storage. From a building management perspective, occupancy durations generally reduce when affected by incidents, suggesting shortening the schedules of heating, ventilation and air-conditioning systems. From a facility management perspective, big changes in occupancy of closed buildings indicate unstable demands for the surrounding equipment (e.g. e-scooters, chargers), and efficiencies may be gained by allocating spaces/schedules to meet the dynamic demand.

Authors

Institutions

Publication Details

Journal
Environment and Planning B Urban Analytics and City Science
Published
2025-05-20
DOI
https://doi.org/10.1177/23998083251343715
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrating activity-based transport and building occupancy models for campus-scale energy management

Aruna Sivakumar, Jacek Pawlak, Huiqiao Hou
Environment and Planning B Urban Analytics and City Science
Building Energy and Comfort Optimization
article

Integrating activity-based transport and building occupancy models for campus-scale energy management

Aruna Sivakumar, Jacek Pawlak, Huiqiao Hou
article en

Abstract

Arrivals and departures lie at the intersection of travel and building occupancy behaviours which dominate the landscape of energy demand in urban areas. Although transport and building systems are clearly linked, existing studies rarely consider the interactions between these systems in their modelling frameworks, thus restricting the policy-relevant scenarios that can be tested. This paper contributes to the field of data-driven energy modelling by proposing a flexible framework to integrate the modelling of travel and building occupancy behaviours, in which a travel simulator is coupled with a building occupancy model through a proposed mesoscopic link. The framework is operationalised in the context of the South Kensington Campus, Imperial College London, using the UK Time Use Survey data and Wi-Fi traceable logs. Implementing the framework for a hypothetical transport incident (i.e. sudden closure of the nearest underground station) generates people’s occupancy and circulation patterns across buildings, thus providing actionable insights for district-level smart grid planning and management. From a district planning perspective, occupancy schedules and dynamics in closed buildings are sensitive to incidents, whereas open and shared buildings are relatively stable. This finding indicates the need for flexible energy controls and smart grids with energy storage. From a building management perspective, occupancy durations generally reduce when affected by incidents, suggesting shortening the schedules of heating, ventilation and air-conditioning systems. From a facility management perspective, big changes in occupancy of closed buildings indicate unstable demands for the surrounding equipment (e.g. e-scooters, chargers), and efficiencies may be gained by allocating spaces/schedules to meet the dynamic demand.

Environment and Planning B Urban Analytics and City Science
Peking University Shenzhen Hospital (CN), Imperial College London (GB)
Engineering and Physical Sciences Research Council, Chinese Government Scholarship
Openalex Percentile: Top 89%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.