Momentum microscopy with combined hemispherical and time-of-flight electron analyzers at the soft X-ray beamline I09 of the diamond light source

The three-dimensional recording scheme of time-of-flight momentum microscopes (ToF-MMs) is advantageous for fast mapping of the photoelectron distribution in (E,k) parameter space over the entire Brillouin zone. However, the 2 ns pulse period of most synchrotrons is too short for pure ToF photoelectron spectroscopy. The use of a hemispherical analyzer (HSA) as a pre-filter allows ToF-MM at such high pulse rates. The first HSA & ToF hybrid MM is operated at the soft X-ray branch of beamline I09 at the Diamond Light Source, UK. The photon energy ranges from 105 eV to 2 keV, with circular polarization available for hν ≥ 145 eV. The HSA reduces the transmitted energy band to typically 0.5 eV, which is then further analyzed by ToF recording. In initial experiments, the overall efficiency gain when switching from the standard 2D (k<sub>x</sub>,k<sub>y</sub>) mode to the 3D (k<sub>x</sub>,k<sub>y</sub>,E<sub>kin</sub>) hybrid mode was about 24. This value is determined by the number of resolved kinetic energies (here 12) and the transmission gain of the electron optics due to the high pass energy of the HSA in hybrid mode (E<sub>pass</sub> up to 500 eV). The transmission gain depends on the size of the photon footprint on the sample. Under k-imaging conditions, the energy and momentum resolution are 10.2 meV (FWHM) (4.2 meV with 200 μm slits and E<sub>pass</sub> = 8 eV) and 0.010 Å<sup>-1</sup>. The energy filtered X-PEEM mode showed a spatial resolution of 250 nm. As examples, we show 2D band mapping of bilayer graphene, 3D mapping of the Fermi surface of Cu, circular dichroic ARPES for intercalated indenene layers, and the sp valence band of Au. Full-field photoelectron diffraction patterns of Ge show rich structure in k-field diameters of up to 6 Å<sup>-1</sup>.

Authors

Institutions

Publication Details

Journal
Ultramicroscopy
Published
2025-05-20
DOI
https://doi.org/10.1016/j.ultramic.2025.114169
Citations
6
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
11.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Momentum microscopy with combined hemispherical and time-of-flight electron analyzers at the soft X-ray beamline I09 of the diamond light source

Tien‐Lin Lee, H. J. Elmers, Jieyi Liu, M. Sing et al.
6 citations
Ultramicroscopy
Advanced X-ray Imaging Techniques
11.30
article

Momentum microscopy with combined hemispherical and time-of-flight electron analyzers at the soft X-ray beamline I09 of the diamond light source

Tien‐Lin Lee, H. J. Elmers, Jieyi Liu, M. Sing, R. Claessen, Matthias Schmitt, O. Fedchenko, Olena Tkach, Deepnarayan Biswas, G. Schönhense
article en
6 citations

Abstract

The three-dimensional recording scheme of time-of-flight momentum microscopes (ToF-MMs) is advantageous for fast mapping of the photoelectron distribution in (E,k) parameter space over the entire Brillouin zone. However, the 2 ns pulse period of most synchrotrons is too short for pure ToF photoelectron spectroscopy. The use of a hemispherical analyzer (HSA) as a pre-filter allows ToF-MM at such high pulse rates. The first HSA & ToF hybrid MM is operated at the soft X-ray branch of beamline I09 at the Diamond Light Source, UK. The photon energy ranges from 105 eV to 2 keV, with circular polarization available for hν ≥ 145 eV. The HSA reduces the transmitted energy band to typically 0.5 eV, which is then further analyzed by ToF recording. In initial experiments, the overall efficiency gain when switching from the standard 2D (k<sub>x</sub>,k<sub>y</sub>) mode to the 3D (k<sub>x</sub>,k<sub>y</sub>,E<sub>kin</sub>) hybrid mode was about 24. This value is determined by the number of resolved kinetic energies (here 12) and the transmission gain of the electron optics due to the high pass energy of the HSA in hybrid mode (E<sub>pass</sub> up to 500 eV). The transmission gain depends on the size of the photon footprint on the sample. Under k-imaging conditions, the energy and momentum resolution are 10.2 meV (FWHM) (4.2 meV with 200 μm slits and E<sub>pass</sub> = 8 eV) and 0.010 Å<sup>-1</sup>. The energy filtered X-PEEM mode showed a spatial resolution of 250 nm. As examples, we show 2D band mapping of bilayer graphene, 3D mapping of the Fermi surface of Cu, circular dichroic ARPES for intercalated indenene layers, and the sp valence band of Au. Full-field photoelectron diffraction patterns of Ge show rich structure in k-field diameters of up to 6 Å<sup>-1</sup>.

UltramicroscopyVol. 276
Johannes Gutenberg University Mainz (DE), University of Würzburg (DE), Diamond Light Source (GB)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 1%
Advanced X-ray Imaging Techniques
11.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.