Impact of Temperature on Electrostatic Precipitator Performance with Varying Electrode Configurations

To study the effects of temperature on electrostatic dust collectors, the electrostatic precipitator (ESP) of different electrode configurations is tested. By studying the effect of temperature on electric halo discharge and particle collection in the range of 450-900 K, under the premise of changing the number of discharge electrodes, different experimental conditions are analyzed. The following related data is compared and analyzed. By comparison of the electric field, flow field, and particle capture characteristics of the two dust collectors, it is proved that temperature is an important impact factor affecting the collection efficiency of electrostatic dust collector particles. The results demonstrate that as temperature increases, the operating voltage of the ESP decreases, and air density changes. This leads to a reduction in both the strength and spatial charge density of the electric field, thereby altering particle movement and, consequently, affecting the performance of the ESP. The particle collection efficiency decreases accordingly. Furthermore, the suppressive influence of higher temperatures on particle retention shows a positive relationship with particle diameter. The electrostatic precipitator, with its different electrode configurations, has a significant impact on particle migration velocity. It has been shown that as the number of discharged electrons increases and the electrode spacing decreases, both the average electric field strength and the space charge density of the ESP increase, which consequently affects dust collection efficiency. For example, the analysis of the different models revealed that the B model exhibited superior dust collection efficiency. Therefore, we can conclude that temperature is a crucial factor affecting the efficiency of static dust collectors with varying electrode configurations.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-05-20
DOI
https://doi.org/10.1021/acsomega.5c00203
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Temperature on Electrostatic Precipitator Performance with Varying Electrode Configurations

Yi Ma, Hang Jerry Qi, Nan Wang, Jun Fu et al.
ACS Omega
Aerosol Filtration and Electrostatic Precipitation
article

Impact of Temperature on Electrostatic Precipitator Performance with Varying Electrode Configurations

Yi Ma, Hang Jerry Qi, Nan Wang, Jun Fu, Liwei Ning, M. T. Cheng, Shuo Gu
article en

Abstract

To study the effects of temperature on electrostatic dust collectors, the electrostatic precipitator (ESP) of different electrode configurations is tested. By studying the effect of temperature on electric halo discharge and particle collection in the range of 450-900 K, under the premise of changing the number of discharge electrodes, different experimental conditions are analyzed. The following related data is compared and analyzed. By comparison of the electric field, flow field, and particle capture characteristics of the two dust collectors, it is proved that temperature is an important impact factor affecting the collection efficiency of electrostatic dust collector particles. The results demonstrate that as temperature increases, the operating voltage of the ESP decreases, and air density changes. This leads to a reduction in both the strength and spatial charge density of the electric field, thereby altering particle movement and, consequently, affecting the performance of the ESP. The particle collection efficiency decreases accordingly. Furthermore, the suppressive influence of higher temperatures on particle retention shows a positive relationship with particle diameter. The electrostatic precipitator, with its different electrode configurations, has a significant impact on particle migration velocity. It has been shown that as the number of discharged electrons increases and the electrode spacing decreases, both the average electric field strength and the space charge density of the ESP increase, which consequently affects dust collection efficiency. For example, the analysis of the different models revealed that the B model exhibited superior dust collection efficiency. Therefore, we can conclude that temperature is a crucial factor affecting the efficiency of static dust collectors with varying electrode configurations.

ACS OmegaVol. 10(21)
Shaoyang University (CN), Education Department of Hunan Province (CN)
Shaoyang University, Natural Science Foundation of Hunan Province
Affordable and clean energy
Openalex Percentile: Top 91%
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.