Influence of Building-Height Variability on Urban Ventilation and Pollutant Dispersion Characteristics

Urban densification associated with rapid urbanization has weakened horizontal ventilation in cities. Previous studies point out that building-height variability can enhance vertical ventilation, while most of them rely on idealized models that overlook the complexity of real urban environments. This study analyzes 20 actual urban blocks using CFD simulations, considering average building height, building density, and height standard deviation. The results show that areas with low-rise, uniform buildings exhibit superior pollutant dispersion, while mid- and high-rise zones experience complex turbulence and pollutant accumulation. Ventilation performance peaks when the height standard deviation ranges between 35 and 40. These findings underscore that optimizing urban form for vertical ventilation requires a combined strategy of density control and height variation. Realistic building group models more accurately capture airflow dynamics and provide valuable insights for the design of effective vertical ventilation corridors and the enhancement of urban pollutant dispersion.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2025-05-17
DOI
https://doi.org/10.3390/atmos16050614
Citations
5
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
4.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Building-Height Variability on Urban Ventilation and Pollutant Dispersion Characteristics

Tieqiao Xiao, Taotao Shui, Lili Cao, Shaojie Zhang
5 citations
Atmosphere
Wind and Air Flow Studies
4.00
article

Influence of Building-Height Variability on Urban Ventilation and Pollutant Dispersion Characteristics

Tieqiao Xiao, Taotao Shui, Lili Cao, Shaojie Zhang
article en
5 citations

Abstract

Urban densification associated with rapid urbanization has weakened horizontal ventilation in cities. Previous studies point out that building-height variability can enhance vertical ventilation, while most of them rely on idealized models that overlook the complexity of real urban environments. This study analyzes 20 actual urban blocks using CFD simulations, considering average building height, building density, and height standard deviation. The results show that areas with low-rise, uniform buildings exhibit superior pollutant dispersion, while mid- and high-rise zones experience complex turbulence and pollutant accumulation. Ventilation performance peaks when the height standard deviation ranges between 35 and 40. These findings underscore that optimizing urban form for vertical ventilation requires a combined strategy of density control and height variation. Realistic building group models more accurately capture airflow dynamics and provide valuable insights for the design of effective vertical ventilation corridors and the enhancement of urban pollutant dispersion.

AtmosphereVol. 16(5)
Anhui Jianzhu University (CN), Hefei Urban Planning & Design Institute (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 7%
Wind and Air Flow Studies
4.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of Building-Height Variability on Urban Ventilation and Pollutant Dispersion Characteristics — Tieqiao Xiao, Taotao Shui, et al. · Atmosphere (2025) | TGRS Research Map | TGRS