Parametric Design of Continuum Robots Using Interlocking Ball Joints

Continuum robots are promising systems for minimally invasive surgical procedures, enabling safe and dexterous access to deep regions in the human body. Their design and fabrication can be adapted to a wide range of application‐specific requirements. Unfortunately, the current lack of standardized methods for producing these designs impedes the development and adoption of new continuum robots (CRs). Herein, a parametric design methodology is introduced for producing a wide variety of CRsbased on application‐specific requirements. This approach is based on interlocking ball joint subunits that enable the generation of modular systems. The methodology is demonstrated by designing a magnetically actuated continuum robot for cardiac ablations. The design is generated using an open‐source parametric computer‐aided design toolbox, and prototypes are experimentally validated in vitro and ex vivo, demonstrating the ability of the toolbox to produce functional systems with minimal effort and input from the user.

Authors

Institutions

Publication Details

Journal
Advanced Intelligent Systems
Published
2025-05-19
DOI
https://doi.org/10.1002/aisy.202500180
Citations
1
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parametric Design of Continuum Robots Using Interlocking Ball Joints

Bradley J. Nelson, Alexandre Mesot, Quentin Boehler, Buse Aktaş et al.
1 citations
Advanced Intelligent Systems
Soft Robotics and Applications
0.67
article

Parametric Design of Continuum Robots Using Interlocking Ball Joints

Bradley J. Nelson, Alexandre Mesot, Quentin Boehler, Buse Aktaş, Sean Lyttle, Florian Heemeyer
article en
1 citations

Abstract

Continuum robots are promising systems for minimally invasive surgical procedures, enabling safe and dexterous access to deep regions in the human body. Their design and fabrication can be adapted to a wide range of application‐specific requirements. Unfortunately, the current lack of standardized methods for producing these designs impedes the development and adoption of new continuum robots (CRs). Herein, a parametric design methodology is introduced for producing a wide variety of CRsbased on application‐specific requirements. This approach is based on interlocking ball joint subunits that enable the generation of modular systems. The methodology is demonstrated by designing a magnetically actuated continuum robot for cardiac ablations. The design is generated using an open‐source parametric computer‐aided design toolbox, and prototypes are experimentally validated in vitro and ex vivo, demonstrating the ability of the toolbox to produce functional systems with minimal effort and input from the user.

Advanced Intelligent SystemsVol. 7(11)
ETH Zurich (CH), Max Planck Institute for Intelligent Systems (DE)
Openalex Percentile: Top 32%
Soft Robotics and Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Parametric Design of Continuum Robots Using Interlocking Ball Joints — Bradley J. Nelson, Alexandre Mesot, et al. · Advanced Intelligent Systems (2025) | TGRS Research Map | TGRS