Refinement of Trend-to-Trend Cross-Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (EPICS) Global Temporally Stable Target

Cross-calibration is an essential technique for calibrating Earth observation satellite sensors, which involves taking nearly simultaneous images of a ground target to compare an uncalibrated sensor to a well-calibrated reference sensor. This study introduces the hyperspectral Trend-to-Trend (T2T) cross-calibration technique utilizing EPICS Cluster 13 Global Temporally Stable (Cluster 13-GTS) as the calibration target, offering better temporal stability than previous targets used in T2T cross-calibration by an absolute difference of 0.4%, between coefficients of variation across all bands excluding CA band. A multispectral sensor-specific normalized hyperspectral profile was developed using the EO-1 Hyperion hyperspectral profile over Cluster 13-GTS to improve Spectral Band Adjustment Factor (SBAF) estimation, capturing sensor-specific Relative Spectral Response (RSR) variations and introducing the ability to use the multispectral sensor-specific hyperspectral profile for calibrating future satellite sensors like Landsat Next with super-spectral bands. SBAFs were derived from EO-1 Hyperion normalized to multispectral sensors, which were interpolated to 1 nm, ensuring precise spectral band adjustments following a Monte Carlo simulation approach for uncertainty quantification. Results show that reference sensor-specific hyperspectral profiles at 1 nm spectral resolution improve SBAF accuracy and exhibit total uncertainty within 5.8% across all bands and all sensor pairs with L8 as the reference sensor. These findings demonstrate that integrating reference sensor-specific high-resolution hyperspectral data and stable calibration targets improves T2T cross-calibration accuracy, supporting future super-spectral missions such as Landsat Next.

Authors

Institutions

Publication Details

Journal
Remote Sensing
Published
2025-05-20
DOI
https://doi.org/10.3390/rs17101774
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Refinement of Trend-to-Trend Cross-Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (EPICS) Global Temporally Stable Target

Juliana Fajardo Rueda, Morakot Kaewmanee, Larry Leigh, Minura Samaranayake
Remote Sensing
Calibration and Measurement Techniques
article

Refinement of Trend-to-Trend Cross-Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (EPICS) Global Temporally Stable Target

Juliana Fajardo Rueda, Morakot Kaewmanee, Larry Leigh, Minura Samaranayake
article en

Abstract

Cross-calibration is an essential technique for calibrating Earth observation satellite sensors, which involves taking nearly simultaneous images of a ground target to compare an uncalibrated sensor to a well-calibrated reference sensor. This study introduces the hyperspectral Trend-to-Trend (T2T) cross-calibration technique utilizing EPICS Cluster 13 Global Temporally Stable (Cluster 13-GTS) as the calibration target, offering better temporal stability than previous targets used in T2T cross-calibration by an absolute difference of 0.4%, between coefficients of variation across all bands excluding CA band. A multispectral sensor-specific normalized hyperspectral profile was developed using the EO-1 Hyperion hyperspectral profile over Cluster 13-GTS to improve Spectral Band Adjustment Factor (SBAF) estimation, capturing sensor-specific Relative Spectral Response (RSR) variations and introducing the ability to use the multispectral sensor-specific hyperspectral profile for calibrating future satellite sensors like Landsat Next with super-spectral bands. SBAFs were derived from EO-1 Hyperion normalized to multispectral sensors, which were interpolated to 1 nm, ensuring precise spectral band adjustments following a Monte Carlo simulation approach for uncertainty quantification. Results show that reference sensor-specific hyperspectral profiles at 1 nm spectral resolution improve SBAF accuracy and exhibit total uncertainty within 5.8% across all bands and all sensor pairs with L8 as the reference sensor. These findings demonstrate that integrating reference sensor-specific high-resolution hyperspectral data and stable calibration targets improves T2T cross-calibration accuracy, supporting future super-spectral missions such as Landsat Next.

Remote SensingVol. 17(10)
South Dakota State University (US)
U.S. Geological Survey
Openalex Percentile: Top 86%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Refinement of Trend-to-Trend Cross-Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (EPICS) Global Temporally Stable Target — Juliana Fajardo Rueda, Morakot Kaewmanee, et al. · Remote Sensing (2025) | TGRS Research Map | TGRS