Optimization of the parameters of the detector of ionizing radiation on the base of waveguide ring resonators with hyperlinked fluoropolymer

We demonstrated the possibility of using the microring resonators based on the slot waveguide for measuring the absorbed dose of ionizing radiation. In order to increase the sensitivity of the waveguide guiding properties to ionizing radiation effects, the slots are filled with hyperlinked fluoropolymer. The optimization of the parameters of the slot waveguides to achieve the maximum detector sensitivity to the ionizing radiation effect has been carried out. The sensitivity of the detector on the base of double-slot waveguides with optimized parameters and a radius of the waveguide bend equal to 67.8 µm is 103.5 µA/kGy (1.035 µA/krad), the measuring range is 85 kGy (8.5 Mrad), and the detector resolution is 0.2 Gy (20 rad).

Authors

Institutions

Publication Details

Journal
Journal of the Optical Society of America B
Published
2025-05-20
DOI
https://doi.org/10.1364/josab.559234
Primary Topic
Silicone and Siloxane Chemistry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of the parameters of the detector of ionizing radiation on the base of waveguide ring resonators with hyperlinked fluoropolymer

Vitaly Reabtsev, Marian Marciniak, Igor Goncharenko, Aliaksandr Ilyushonak
Journal of the Optical Society of America B
Silicone and Siloxane Chemistry
article

Optimization of the parameters of the detector of ionizing radiation on the base of waveguide ring resonators with hyperlinked fluoropolymer

Vitaly Reabtsev, Marian Marciniak, Igor Goncharenko, Aliaksandr Ilyushonak
article en

Abstract

We demonstrated the possibility of using the microring resonators based on the slot waveguide for measuring the absorbed dose of ionizing radiation. In order to increase the sensitivity of the waveguide guiding properties to ionizing radiation effects, the slots are filled with hyperlinked fluoropolymer. The optimization of the parameters of the slot waveguides to achieve the maximum detector sensitivity to the ionizing radiation effect has been carried out. The sensitivity of the detector on the base of double-slot waveguides with optimized parameters and a radius of the waveguide bend equal to 67.8 µm is 103.5 µA/kGy (1.035 µA/krad), the measuring range is 85 kGy (8.5 Mrad), and the detector resolution is 0.2 Gy (20 rad).

Journal of the Optical Society of America BVol. 42(8)
University of Civil Protection (BY)
Affordable and clean energy
Openalex Percentile: Top 92%
Silicone and Siloxane Chemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.